Nike Star variable heat output.
OUTPUT
OUTPUT
HEAT
HEAT
(kcal/h)
(kW)
20000
23,3
19000
22,1
18000
20,9
H
17700
20,6
E
A
16000
18,6
T
15000
17,4
I
N
14000
16,3
G
13000
15,1
12000
14,0
11000
12,8
10000
11,6
9000
10,5
8000
9,3
6000
7,0
Domestic
N.B.: Gas flow rates refer to heat output below 15°C and pressure of 1013
mbar. Burner pressure values refer to use of gas at 15°C.
Nike Star technical specifications.
Nominal heating capacity
Min. heating capacity
Nominal heat output (useful)
Min. heat output (useful)
Useful heating efficiency at nominal output
Useful heating efficiency at 30% nom. output
Heat loss at shell with burner On/Off
Heat loss at flue with burner On/Off
Diam. nozzles
Feed pressure
Max. working pressure heating circuit
Max. working temp. heating circuit
Adjustable temp. heating
Total volume expansion tank
Expansion tank precharge
Water content of generator
Available head with flowrate 1000 l/h
Useful heat output hot water production
Domestic hot water adjustable temp.
Flow limiter
Min. pressure (dynamic) domestic circuit
Max. working pressure domestic circuit
Min. drawing domestic hot water
Drawing capacity in continuous service (∆T 30° C)
Specific capacity ( ∆T 30° C)
Min. pressure for flow limiter capacity
Weight of boiler full
Weight of boiler empty
Electrical connection
Nominal absorption
Installed electrical power
Power absorbed by circulating pump
Appliance electrical system protection
Fumes flowrate in mass at nominal output
Fumes flowrate in mass at min. output
CO
at Nom./Min. Q.
2
CO at 0% O
at Nom./Min. Q.
2
NO
at 0% O
at Nom./Min. Q.
x
2
Fumes temp. at nom. output
Fumes. temp. at min. output.
Resistance boiler fumes circuit
Flue temperature values refer to air inlet temperatures of 15°C.
NATURAL GAS (G20)
GAS
NOZZLES PRESSURE
FLOWRATE
BURNER
BURNER
(mbar)
(mm H20)
(m3/h)
2,71
10,6
108
2,58
9,7
99
2,45
8,7
88
2,41
8,4
85
2,18
6,9
70
2,05
6,1
62
1,92
5,3
54
1,79
4,6
47
1,66
4,0
40
1,52
3,4
34
1,39
2,8
29
1,26
2,3
23
1,13
2,1
21
0,85
1,2
12
BUTANE (G30)
GAS
NOZZLES PRESSURE
FLOWRATE
BURNER
BURNER
(mbar)
(mm H20)
(kg/h)
2,02
27,5
281
1,93
25,1
256
1,82
22,5
229
1,79
21,7
222
1,62
17,8
182
1,53
15,7
160
1,43
13,8
141
1,33
12,0
122
1,23
10,3
105
1,14
8,7
89
1,04
7,3
74
0,94
6,0
61
0,84
4,7
48
0,64
2,7
28
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
%
%
%
%
G20
mm
1,30
mbar (mm H
O)
20 (204)
2
bar
°C
°C
l
bar
l
kPa (m H
O)
2
kW (kcal/h)
°C
l/min
bar
bar
l/min
l/min
l/min
bar
kg
kg
V/Hz
A
W
W
-
G20
kg/h
66
kg/h
58
%
5,5/2,5
ppm
90/12
ppm
116/65
°C
94
°C
74
Pa
PROPANE (G31)
GAS
NOZZLES PRESSURE
FLOWRATE
BURNER
BURNER
(mbar)
(mm H20)
(kg/h)
1,99
35,3
360
1,90
32,2
328
1,80
28,9
294
1,77
27,9
285
1,60
22,9
233
1,50
20,2
206
1,41
17,7
180
1,31
15,3
157
1,21
13,2
134
1,12
11,2
114
1,02
9,3
0,93
7,7
0,83
6,4
65
0,63
3,6
25,6 (22002)
10,7 (9174)
23,3 (20000)
9,3 (8000)
90,9
89,2
2,8/1,13
6,3/0,51
G30
G31
0,77
0,77
29 (296)
37 (377)
3
90
35 - 80
6
1,0
3,5
23,03 (2,35)
23,3 (20000)
35 - 55
8
0,26
10
2,5
11,1
10,7
1
34
30
230/50
0,40
85
63
IPX4D
G30
G31
65
66
57
59
6,5/2,9
6,3/2,8
170/19
48/14
200/97
150/75
95
97
75
76
1,3
ES
PT
GR
PL
TR
95
CZ
78
37
HR
SL
HU
RU
RO
GB
107