Faults
Smell of gas.
The pilot light does not
ignite.
The pilot light goes out.
The fl ame is yellow.
Burner control knob is stiff .
3320070_ut_GB_rev.1

FAULT

TROUBLESHOOTING

For all requirements contact the agents or
the headquarters of Angelo Po which can be
found in the contacts section of the website
http://www.angelopo.com.
Causes
Occasional leak because fl ame
has gone out.
The spark ignition devices are
not working.
Air in pipelines due to long
period out of use.
The thermocouple has not
warmed up enough.
Burner dirty, heat exchange
pipes clogged, condensation
drips.
Gas control valve malfunction.
- 13 -
Important
Remedies
Turn off the gas supply tap and
ventilate the room.
Check that the ignition devices are
in good working order. Light by
hand with a naked light.
Important
Contact the after-sales service.
Make more attempts to light the
Make more attempts to light the
Important
Contact the after-sales service.
Important
Contact the after-sales service.
fl ame.
fl ame.