Installation
Avoid dusty or smoky environments or locations near sources of heat.
For proper installation, use the template supplied with the product.
1.
Position the top of the template at a height of 1.65m.
2.
If you are going to use an embedding box to pass the wiring through, make sure that it is in line with the holes
corresponding to the box model chosen and fix the connector. If you prefer to fix the connector directly to the
wall, make four 6mm holes at the points indicated (A), insert the wall plugs supplied and screw in the connector.
3.
Pass the installation wires through the middle hole and connect them to the removable terminals as shown in the
wiring diagrams. Before connecting the removable terminals to the monitor, configure the switch as indicated
below.
4.
Connect the removable terminals to the monitor and place the monitor in front of the connector, making sure the
fixings line up. Move the monitor downwards to secure it.
Installation terminals
For ease of installation, the installation terminals are removable and supplied in a separate bag. Once the
terminals are wired, place them in position.
ON
1
2
3
4
5
SA
GND
HZ
HZ

Configuration switches

Switches 1 to 5.
These assign the address of the corresponding monitor to its call button on the door panel. Switches to 5 must
remain in the OFF position.
ON
1
2
3
4
5
Apartment
Switches 6 to 7.
These define whether the monitor is master or slave. Each apartment must have one master monitor, and only
one.
ON
1
2
3
4
5
Master
Switch
. 8
This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable ends.
Deactivate it only in intermediate monitors.
Golmar reserves the right to make any modifications without prior notice
ART 7/G2+ MONITOR DESCRIPTION
( ) J
BUS IN:
BUS OUT:
6
7
8
SA GND
,
HZ HZ
,
Connect only on the master monitor. The signal received is then
transmitted to the slave monitors in the same apartment through the
BUS.
( ) I
ON
6
7
8
1
2
3
4
5
1
Apartment
ON
6
7
8
1
2
3
4
5
Slave 1
Communication bus input to monitor (non-polarised).
Communication bus output to additional monitor (non-polarised).
:
Auxiliary call repeater (max 50mA/12V), relay SAR-12/24.
:
Apartment front door button input:
ON
6
7
8
1
2
3
4
5
2
Apartment
ON
6
7
8
1
2
3
4
5
Slave 2
Rev.0219
ON
6
7
8
1
2
3
4
5
3
Apartment
ON
6
7
8
1
2
3
4
5
Slave 3
TART 7/G2+ EN
4
6
7
8
4
6
7
8
EN