Adeunis RF ARF868 Guia Del Usuario página 95

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

ARF868 Radio Modems - User guide version V1.6
«W»<cr><lf>, se rifiuta il comando perché la configurazione richiesta non è autorizzata.
«CM» <cr><lf>, se accetta l'ingresso in modalità di regolazione
Tabella dei comandi AT:
Comando
Descrizione
ATS<n> ?
Returns the contents of register n
ATS<n>=<m>
Transfer the value m to register n
AT/S
Display as a list, the content of each User register
AT/V
Display the firmware version
ATR
Restore the content of registers with default values.
This command must be followed by an AT&W
command and a module reset to ensure that all
parameters have been applied.
ATT00
Enables test mode: Sends a predefined frame (see
note1).
Exit test mode ATT00 : ESC (0x1B)
ATT01
Enables test mode: Reception and control
frames received in opposite to ATT00 (see note1).
Exit test mode ATT01: ESC (0x1B)
ATT02
Starts the Scan Free mode
ATT03 <c> <t>
Scan of channel «c», during a «t» period , with :
-
-
ATX3
Automatic registers programming for X3Pro modems
compatibility :
-
-
-
-
Other registers to their default values.
AT&W
Save the register configuration in E2PROM.
AT&RST
Restart the modem
AT0
Exit command mode
Exemple d'une suite de commande et des réponses correspondantes telles qu'on pourrait les voir sur un terminal :
Sintassi del comando
+++
ATS254=3
ATS200=9
ATS200=527
ATS231=0
ATS200 ?
ATS231 ?
AT&W
ATO
Interpretazione dell'esempio precedente: l'utente ha voluto memorizzare una nuova configurazione radio (canale 527, potenza 27 dBm) dopo
aver inserito dei parametri erronei (risposta E) e una richiesta di configurazione non autorizzata (risposta W). Il modem non consente né il salva-
<c> value on three digits.
<t> value from 1 to 999, by step of 1s
S210 = 3 -> 9600 bauds
S215 = 1 -> RS232
S220 = 1 -> Addressed
S252 = 0 -> Source address = 0
Descrizione
Request for entry into command mode
Request for RF data rate at 9.6kbps
Request for channel selection = 9
Request for channel selection = 527
Request for RF power at 27dBm
Returns S200 register value
Returns S231 register value
Storage request of the registers status
Request to exit command mode
Risposta
Sn=y where y represents the contents of register n
«O»<cr> if operation OK
«E»<cr> if error
« W» if the operation has a configuration problem.
Sxxx=y<cr><lf> for each register
Adeunis RF ARF868<val> ?????
«O»<cr> if operation OK
«E»<cr> if error
«O»<cr> if operation OK
«E»<cr> if error
«O»<cr> if operation OK
«E»<cr> if error
«Returns for each channel, its number and RSSI value associated :
Cxxx=-090dBm<cr><lf>
The command returns three values of RSSI: mini, medium and maximum.
«O»<cr> if operation OK
«E»<cr> if error
«O»<cr> if operation OK
«E»<cr> if error
«O»<cr> if operation OK
«E»<cr> if error
«O»<cr> if operation OK
«E»<cr> if error
Sintassi della risposta sulla riga seguente
CM
O
E -> invalid channel !
O
O
S200=527
S231=0
W (the selected channel is not available at 9.6kbps RF data rate)
The value storage will not be performed.
W (the selected channel is not available at 9.6kbps RF data rate)
The Exit will not be performed.
Page
20
of 25
Tabla de contenido
loading