8
APPLICABLE CONTROLS
To improve Cooling/Heating effect
When only poor cooling/heating effect is obtained due to installation place of the indoor unit or construction of the
room, the detection temperature of cooling/heating can be changed.
• Remove the cover of the electric parts box by taking off the mounting screws (3 positions) and pushing the
hooking section. (The cover of the electric parts box remains hanged to the hinge.)
• There are the selector switches (SW01) on the P.C. board of the electric parts box.
The setting of the detection temperature can be changed by combining No.1 to No.4 switches of the selector
switches (SW01). Adjust the setting of the detection temperature according to the right table.
Setting at shipment
No.1
No.2
No.3
No.4
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
19
COOL/DRY
HEAT
(°C)
(°C)
–2
–2
–2
+4
–2
+2
–2
0
+4
–2
+4
+4
+4
+2
+4
0
+2
–2
+2
+4
+2
+2
+2
0
0
–2
0
+4
0
+2
← Factory setting
0
0
ON
6H
SW01
1
2 3 4
TS ADJUST
ON
ON
6H
SW02
Tabla de contenido