IRSAP 471M0918 Manual Del Usario página 7

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
Mixed functioning for towel
heaters with power
regulation
IRSAP SPA
45031 Arquà Polesine (RO) Italy
Tel. +39 0425 466611 - Fax +39 0425 466662
Website: http://www.irsap.com
IR GROUP SARL
19,Chemin de la Plaine 69390 Vourles (France)
Tel. +33 04 28 00 01 67 -
Fax +33 04 72 31 86 40
Web: http://www.irsap.com;
IRSAP-RHOSS Clima Integral, S.L.
Oficina y Almacèn: P.I.CAMI RAL
Leonardo da Vinci,4 08850 Gavà (Barcelona)
Tel. 93 633 47 00 - Fax 93 633 47 04
www.irsap.com
IRROM Industrie S.R.L.
Str. Pricipalà 1/A, Sat Fundàtara, Iclod 407336,
jud. Cluj, Romània
Tel: +40 (0)264 263400 –
Fax: +40 (0)264 263404
Web: www.irsap.ro
The towel heaters with the electric resistance inserted is an electric appliance with the following characteristics:
• feeding - Voltage 230V, 50Hz, 1Ph
• power absorbed by the electric heater 300÷1800 Watt. (The combination of the electric heater and the model of towel heaters permits the latter's
surface to be maintained at a temperature below around 70°C).
• insulation Class II
• protection degree IP44
• resistance thermostat calibrated to 90°C
• resistance thermalfuse calibrated to 152°C
• length of electrical cable 1200 mm
• electronic control with power regulation.
The electronic control consists of electronics which allows the selection working power of the cartridge.
The hydraulic towel heater can be equipped with a resistance for extra electric heating.
Even when the main hydraulic heating system is off, the electric resistance can be switched on to keep towels always warm and dry.
The towel heater must be installed by qualified personnel.
Fasten the towel warmer to the wall by following the attached assembly instructions.
Assembly must be performed by a specialized company in respect of the regulations in force.
When installing the towel rail the IEC 60364-7-701 according to the edition in force must be complied.
The towel heater must be installed in such way that the socket is accessible and that it is not located immediately beneath a fixed current socket.
To supply towel warmer, an omnipolar switch with at least 3 mm of distance between contacts must be employed.
When installing in bathrooms or in shower-rooms, the appliance should be installed in such a way that the switch and other controls cannot be reached
by people using the bath or the shower. (see Fig. 5)
The towel heater must not be installed immediately beneath a fixed current socket.
In order to assemble the cartridge vertically while keeping the hydraulic connection centers below, use a ½" 3-way tee connector.
The position of the hydraulic connection centers is shown in Figures 1÷4. The use of two tee connectors permits both easier installation and better
aesthetics. It is recommended to install this towel warmer in such a way that the lowest heating pipe is at least 600 mm above the floor to avoid risks of
scalds for small children.
Proceed as follows to install the electronic control on the towel warmer (see Fig. C):
• Before performing any operation, make sure that the power supply cord is not plugged into the socket.
• Whenever a malfunction occurs in the electronic control or the device's power supply cord, switch it off and do not touch it.
• Repair must be performed only by the Manufacturer or an authorized technician.
Failure to comply with the above may compromise the safety of the entire system.
1) Position the o-ring on the threaded connector in position (1).
2) With the front of the electronic control oriented in the desired position, connect the power supply wires. Make sure that the Fast-on covers are in place
over the connections (2).
3) Insert the electronic control with its side (A) on the connector (B) of the electric heater until it comes into contact as far as it can go.
4) Fasten the room electronic control using the screw and the appropriate setscrew wrench (3).
5) IMPORTANT! Do not rotate the electronic control box after it has been fastened in place.
6) Make sure that the local mains voltage is the same as the value indicated on the control electric data label.
7) Plug the power supply cord into the current socket.
Fig.1
L' : towel heaters hydraulic connection center
(mm)
Cod. 471M0918
2
2
TECHNICAL CHARACTERISTICS
INSTRUCTIONS FOR USING THE ELECTRONIC CONTROL (fig. A)
ASSEMBLING THE ELECTRIC HEATER
Fig.2
Fig.3
A : angle valve dimensions.
B
Alimentazione
O-ring
1
Power supply
Joint torique
Alimentation
Stromversorgung
Alimentación
Alimentare
2x Faston 6.2x0.8
Fig.C
2x Flachstecker 6.2x0.8
A
3
Vite di fissaggio
Retaining screw
Vis de fixation
Befestigungsschraube
Tornillo de fijación
Surub de fixare
B
Alimentazione
O-ring
1
Power supply
Joint torique
Alimentation
Stromversorgung
Alimentación
Alimentare
2x Faston 6.2x0.8
Fig.C
2x Flachstecker 6.2x0.8
A
3
Vite di fissaggio
Retaining screw
Vis de fixation
Befestigungsschraube
Tornillo de fijación
Surub de fixare
ENGLISH (UK)
MIXED OPERATION
INSTRUCTIONS
Fig.4
Dimensions
Potenza
LED
-
16 %
+
-
22 %
+
-
28 %
+
-
34 %
+
-
40 %
+
-
46 %
+
-
52 %
+
-
58 %
+
-
Fig.B
64 %
+
-
70 %
+
-
76 %
+
-
82 %
+
-
88 %
+
-
94 %
+
-
100 %
+
Fig. 5