Kit Contents; Assembly; Descriptions And Controls - Gunson GASTESTER G4125 Manual

Ocultar thumbs Ver también para GASTESTER G4125:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23

1. Kit Contents

2. Assembly

1. Kit Contents
1. Gastester instrument including collector box and pulse pump/water trap assembly
2. Metal exhaust probe with retaining springs
3. Flexible plastic pipes (3 lengths)
4. Instruction handbook
2. Assembly
• In cold conditions, warming the various plastic pipes will assist assembly.
• Press the shortest pipe onto the lower port of the pulse pump/water trap as shown in the
diagrams Figures 1 and 2. This is the automatic water drain.
• The longest plastic pipe is connected to the pulse pump inlet (centre port) and the other end
to the aluminium exhaust probe tube.
• Connect the remaining plastic pipe between the pulse pump (top) outlet and the collector box
inlet. (This connection is intentionally vented at the inlet boss). The connection to the collector
box inlet needs to be pressed fully home.
4
DISPLAY:
This is calibrated in volume percent carbon monoxide (CO%).
CALIBRATION CONTROL:
This is used to set the reading of the display to show 2.0% at the start of the tests, before the
probe is inserted into the exhaust pipe.
Note: The calibrate position represents what the instrument should register when the
probe is in fresh air. It is coincidental that air should measure the same as exhaust gas
with 2% CO. When the probe is subsequently inserted into the exhaust pipe, the display of
the instrument may increase or fall from the calibrate condition.
TWO CORE CABLE WITH CLIPS:
(for connecting to the car battery)
EXHAUST PROBE:
The aluminium pipe is for insertion into the exhaust pipe and is held in position by the metal
Figure 1
springs which press against the inside of the exhaust pipe.
NB: In use the pipe from the exhaust probe should slope down continuously to the pulse pump/
water trap so that water runs down and may be automatically expelled from the drain pipe.
Figure 2