Troubleshooting Tips - MasterCool 55200 Manual De Instrucciones

Ocultar thumbs Ver también para 55200:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

B. F or the best leak detection results, the probe should be moved across the leak detection area at the rate
of 1" - 2" per second (25 - 50mm per second) and held 1/4" (5mm) away from the surface. An increase
in the alarm rate will indicate a leak. T o confirm the correct leak location, blow shop air around the
suspected leak area, move the probe into fresh air, reset and reinspect.
C . W hen inspecting in contaminated or high humidity areas, erratic alarming may occur. F or best results in
these areas, allow the unit to adjust to the existing environment before inspecting. P ressing the RE SE T
button will adjust the unit to an existing environment.
SENSO R TIP REPLACEMENT
The sensor tip performs at full potential for approximately 20 hours. As the tip wears, it will require
replacement. Signs of a warn tip are erratic and irregular alarm response in clean air environments. Before
replacing the tip, make sure that it is free of grease, moisture, dust and dirt. T o remove any of these
materials, use compressed air or alcohol. Make sure the sensor tip is completely dry before using.
UV/BLUELIG HT REPLACEMENT
T o remove, pull the LE Dstraight out of the socket fixture. T o install, press the LE Dinto the socket fixture
with the long terminal to the outside.
TRO UBLESHO O TINGTIPS
W hen the unit starts to display an erratic or irregular alarm response, check or change the sensor tip or the
battery (to check the battery, refer to battery test procedure).
W ARRANTY
The product is warranted for a period of one year from the date of purchase to the original purchaser. A
repair or replacement will be made at no charge with proof of purchase. Damage caused by tampering or
improper use will void warranty. This warranty does not cover batteries, sensor tips or other materials that
wear out during normal use. BE FO R ER E TU R NINGTH EU NIT , P LE ASER E P LAC EO RC LE ANTH ESE NSO RTIP
ANDC H E C KBA TTE R IE S. This warranty is given in lieu of any other warranty, express or implied, including,
without limitation, any implied warranty or merchantability or fitness for a particular use.
F or additional assistance, call 888-825-6989
P ART
P ART NUMBER
Sensor Tip
55100-SE N
LE DBulb
53515-B
W ARNING !
• Pressurized systems can leak
• Keep self and tools clear of moving parts
• W ear safety shield (U ser and bystander)
• Pressurized leaks and breathing vapors may cause injury
• DONO T breathe refrigerant vapors!
Design Certified by MET LABO RATO RIESINC. to meet SAEJ1627 for R134a, R12 and R22.
MADEINUSA
www.mastercool.com
3
Tabla de contenido
loading

Tabla de contenido