Duty Cycle
Range
0.5% - 99.9%
Input Voltage: 2 Vp – 50 Vp
Frequency Range: 4 Hz - 1 kHz
Pulse Width
Range
0.5 ms - 20 ms
Input Voltage: 2 Vp – 50 Vp
Dwell Angle
Number of Cylinder
4 cylinder
5 cylinder
6 cylinder
8 cylinder
Input Voltage: 2 Vp – 50 Vp
Max. Allowable RPM of Engine: 20000 RPM
Tach (rotation speed)
2-stroke engine: 60 – 20000 RPM
4-stroke engine: 120 – 20000 RPM
Input Voltage: 2 Vp – 50 Vp
Max. Allowable RPM of Engine: 20000 RPM
OPERATING INTRODUCTION
Using Relative Mode
Selecting Relative mode causes the meter to store the present reading on the screen as a reference for
subsequent measurements.
1. Press the
reading on the screen as a reference for subsequent measurements, and
as an indicator. The screen reads zero.
2. When you perform a new measurement, the screen will show the difference between the reference
and the new measurement.
3. Press the
Note:
1. When in Relative mode, the actual value of the object under test must not exceed the full-scale reading
of the selected range. Use a higher range if necessary.
2. Relative mode is available only for voltage, current, resistance, capacitance, and temperature
measurements.
MANUAL RANGING AND AUTORANGING
The meter defaults to autorange mode in measurement functions which have both autorange mode and
manual range mode. When the meter is in autorange mode, AUTO is displayed.
1. Press the RANGE button. The meter enters the manual range mode, and AUTO turns off. Each press of
the RANGE button increases the range. After the highest range, the meter wraps to the lowest range.
2. To exit the manual range mode, press and hold down the RANGE button for about 2 seconds. The
meter returns to the autorange mode.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Range
0 – 90°
0 – 72°
0 – 60°
0 – 45°
Range
button momentarily. The meter enters the Relative mode and stores the present
button again, the meter will exit the Relative mode and the symbol
Tel.: 02196 720480
Fax.: 02196 7204820
Resolution
0.1%
Resolution
0.1 ms
Resolution
0.1°
Resolution
<10000RPM: 1 RPM
>=10000RPM: 100 RPM
Accuracy
± (2.0% + 7)
Accuracy
± (2.0% + 3)
Accuracy
± (2.5% + 2)
Accuracy
± (0.5% + 3)
appears on the screen
will disappear.
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed