Fleck ELECTRONIC SE Manual De Uso página 27

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

MASTER PROGRAMMING MODE
2510SE, 2750SE, 2850SE, 2900SE, 2910SE, 4600SE, 5000SE,
5600SE, 8500SE, 9000SE, 9100SE AND 9500SE
Down flow regeneration valves (D
2510SE, 2750SE, 2850SE, 2900SE, 2910SE, 4600SE,
5000SE, 5600SE, 9000SE, 9100SE, 9500SE
Cycle 1: Backwash
1-5.0
Preset: 5 minutes
Cycle 2: Brine & Slow rinse
230.0
Preset: 30 minutes
Cycle 3: Rapid rinse
3-5.0
Preset: 5 minutes
Cycle 4: Brine refill
4-5.0
Preset: 5 minutes
Up flow regeneration valves (U
Filter Valves
2510SE, 2750SE, 2850SE, 2900SE, 2910SE, 4600SE, 5600SE
Cycle 1: Backwash
115.0
Preset: 15 minutes
Cycle 2: Not used
2-0.0
Preset: 0 minute
Cycle 3: Rapid rinse
3-5.0
Preset: 5 minutes
Cycle 4: Not used
4-0.0
Preset: 0 minute
B
2750SE, 2900SE, 2910SE, 5000SE, 5600SE
Cycle 1: Brine & Slow rinse
130.0
Preset: 30 minutes
Cycle 2: Backwash
2-5.0
Preset: 5 minutes
Cycle 3: Rapid rinse
3-5.0
Preset: 5 minutes
Cycle 4: Brine refill
4-5.0
Preset: 5 minutes
OWN FLOW
8500SE
Cycle 1: Rapid rinse tank
1-5.0
in Stand by
Preset: 5 minutes
Cycle 2: Backwash
2-5.0
Preset: 5 minutes
Cycle 3: Brine & Slow rinse
330.0
Preset: 30 minutes
Cycle 4: Brine refill
4-5.0
Preset: 5 minutes
P FLOW
5000SE
Cycle 1: Not used
1-0.0
Preset: 0 minute
Cycle 2: Backwash
215.0
Preset: 15 minutes
Cycle 3: Rapid rinse
3-5.0
Preset: 5 minutes
Cycle 4: Not used
4-0.0
Preset : 0 minute
ELECTRONIC SE
)
E
N
G
L
I
)
S
H
Tabla de contenido
loading

Productos relacionados para Fleck ELECTRONIC SE

Tabla de contenido