Problems , Causes And Solutions - GYS GYSTECH 7000 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

With this mode, the charger provides a voltage of 16,5V ± 0,2V with a limited current of 1,5A ± 10%.
If the battery is deeply discharged (4,5V), the function will be active during 3 hours maximum. As
soon as the battery is accepting the charge, the charger will shift automatically to the charge mode :
the indicator "recover" blinks differently (0.5s ON / 1s off) and the charge indicators blink according to
the evolution of the charge.
MODE 13,6V/Max.
This function is useful to maintain the charging process during an extended period (for instance:
wintering) the 12V batteries, waterproof or without maintenance (SLA, VLRA, AGM, GEL) from 14 to
230Ah. It is particularly adapted for batteries which capacitance should always be at the maximum, as
for instance golf cars, power sweeper, or batteries used for emergency...
Select the mode by pressing
7000 will start the maintenance charge with a constant voltage of 13,6V ± 0,2V and with a limited
current of 5A ±10%. The protections anti-spark and against the overloads are activated.
MODE SUPPLY 5A.
This function changes your battery charger into a power supply (without any need to connect a
battery). The charger provides a voltage of 12V with a limited current of 5A±0,5A. With this mode, the
anti-spark system is disabled. However, the protection against the polarity reversal keeps active.
To choose this function, press 3 seconds on
P
ROTECTION
Gystech 7000 charger is protected against short circuits and polarity inversion. Its anti-sparck system
avoids any spark while connecting the charger to the battery (inactive system with the supply mode).
The charger protects itself (charging interruption +
< 4,5V±0.5V for a 12V battery or < 16V±0.5V for a 24V battery).
Gystech 7000 charger is protected by a thermal sensor. During the charging process, if the charger
becomes too hot or due to extreme ambient temperature, the power output is automatically reduced
to protect itself from damage. Charger increases power automatically when the ambient temperature
drops.
,
PROBLEMS
CAUSES AND SOLUTIONS
In case of problem, the charger automatically switches on protection mode and the power
indicator lights on. The system will remain in that position until the user intervenes.
Problem
Indicator
switched
on
Indicators
and
switched on
after having pressed
on
, the charge
indicators blink
, until the indicator 13,6V/Max lights. With this function, Gystech
.
Causes
 Short circuit
 Circuit open
 Battery voltage
< 4,5V ± 0,5 (for a 12V battery)
or <16V± 0,25 (for a 24V battery)
 The charger is in diagnostic
process for more than 7 hours
 in Main Charge Process for more
than 40 hours
Polarity reversal
The charger analyses if it detects a
well charged battery of 12V or a
deeply discharged one of 24V
(automatic selection of the
voltage)
indicator switched on if the battery voltage is
1- Check that there is no voltage loss
in the vehicle circuit
2- Check that the clamps are well
connected
3- After corrections, if the indicator
is still on, the sulfated or damaged
battery may be replaced (nb : are you
in 12V or 13,6V mode maximum ?
Please try the recovery function)
Check that the clamps are well
connected
Normal behaviour of the charger :
Wait for the end of the analysis (1 or
2 minutes)
Solutions
10/28
Tabla de contenido
loading