General characteristics

- Electronic protection against short-circuits in output.
- Power supply suspend.
- Excess temperature (110 C in the power radiator) detector. In the event of overheating caused by a
ventilation obstruction, a safety device will be triggered. When temperature conditions revert to
normal this devise switches off automatically.
- Digital keypad for microphone volume, auxiliary volume, treble and bass.
- Control device for attenuator with maximum level restoration (three wires) incorporated.
- Input 1: balanced microphone, phantom power supply with remote control input (TM1).
- Input 2: auxiliary with remote control input (TM2).
- Signal input/output connection for audio processors (EG-31, etc.)
- Signal output for other amplifiers, with remote-controlled device for attenuators.
Indicators:
- On/off
- Modulation
- Luminous digital display
Power supply:
- 230 VAC at 50/60 Hz
Optional accessories:
- WX-19
. Antilarsen module.
- WX-3
. Handle / bracket for mounting on 19" rack
- CA-01
. Signal lead
- CA-32
. EG-31 insertion cable.
NOTE:
The
AX-459
sensitivity of the auxiliary input from 770 mV to 250 mV (see graphic).
amplifier has a plug-in connection jumper which allows the user to change the
610.105A