Working on the electrical system may only be carried out by a professional electrician!
Fault
Pump does not run
Pump does not draw
Pump does not switch off
Pump discharge rate
insufficient
Thermal circuit breaker
shuts down the pump
www.graf.info
7. Fault finding and corrective action
Cause
- No electrical power
- Pump impeller jammed
- Suction valve is not in the water
- Pump impeller without water
- Air in the suction pipe
- Blocked suction basket
- Max. Suction height or length of
suction pipe has been exceeded
- Possibly an outlet is open (water
left running)
- Pressure hose or outlet is
leaking
- Suction height too high
- Blocked suction basket
- Dirt in system equipment
- Pump head height too high
- Overloading due to dirt in the
motor housing
25 / 50
Corrective action
- Plug into or check the electrical
supply
- Professional pump overhaul or
service and cleaning
- Suction valve should be
brought below the waters
surface
- Fill the system with water
- Air bleed the system and check
for leaks
- Clean the suction baske
- Check the suction height or
change the pump position or use
a submersible pump
- Close the outlet
- Repair the leaking pressure
hose or outlet
- Check the suction height or
change the pump position or use
a submersible pump
- Clean the suction basket
- Clean all system components
and overhaul or service the
pump from professionals
- Check the pump head height , or
change the pump position or use
a larger pump
- Professional pump overhaul or
service and cleaning
- Prevent the drawing in of dirt
and foreign objects