Solenoid valve usage instructions
The solenoid valve can be operated for closing in two ways:
1. An electrical impulse of 1 second (9 - 12V)
2. By pressing the red button (you must first remove the plastic protective
cover).
After this operation, the solenoid valve remains closed.
Note: The protective cover must remain in place during the use of the solenoid
valve, because it has a protective role against accidental actuation.
To unlock the solenoid valve, allowing the gas flow, pull the red button vertically
upwards. The solenoid valve will remain open.
User manual
6