Error code
E/3
GB
E/4
E/5
E/6
description
Unsustable pot, e.g.
lost of the magnetic
characteristics because
of temperature in the
bottom.
Unconfigured induction
modul (all induction
modul answer to UI, but
any element is related
to the effected cooking
zone).
No communication
between UI and
inducation modul.
Main power disturbace .
Possible causes
Pot creates on the
modul an improper
operating point which
can destroy devices,
e.g. IGBT.
Induction modul is not
configured.
No power supply of
induction modul
Mal cabeling or defect
of.
1. Failure in main power
frequency detection.
40
Error recovery
1. the error is
automaticly cancelled
after 8s and the cooking
zone can be used
again. In case of further
upcoming errors the post
have to be changed.
2. the modul has to be
changed if the error
comes without an pot on
the cooking zone.
1. Delet the hob
configuration and
activate the manual
configuration.
2. Start the UI service
menue to configure the
imduction modul.
3. If the listed points are
not succesful replace
the modul.
Check power and lin
connections is the
connention ok, replace
the modul.
Check main power
voltage and frequency,
if ok.