INTERFACE SIGNALS

Binary signals
Binary code is a standardized way to control outputs that are used for fl oor displays. The benefi t is that you
use less output signals to control multiple signals. I.e. there are only 3 signals needed to display 7 fl oors, 4
signals to display 15 fl oors, 5 signals to display 31 fl oors etc.
Example:
Floor
Code
0
0000
1
0001
2
0010
3
0011
4
0100
5
0101
6
0110
7
0111
GRAY CODE SIGNALS
Gray code is a slightly more rare way to control fl oor displays.
It is often used on older controllers.
Example:
Floor
Code
0
0000
1
0001
2
0011
3
0010
4
0110
5
0111
6
0101
7
0100
DECIMAL SIGNALS (ONE-FLOOR-PER-PIN)
The old way to control fl oor displays are called Decimal or one-fl oor-per-pin.
One output signal is needed for every fl oor, i.e. 8 outputs for 8 fl oors.
Example:
Floor
Code
1
10000000
2
01000000
3
00100000
4
00010000
5
00001000
6
00000100
7
00000010
8
00000001
© 2009 SafeLine and all the SafeLine products and accessories are copyrighted by law.
Floor
Code
8
1000
9
1001
10
1010
11
1011
12
1100
13
1101
14
1110
15
1111
Floor
Code
8
1100
9
1101
10
1111
11
1110
12
1010
13
1011
14
1001
15
1000