Temperature Guidelines; Chemical Warming And Cooling; Nitrogen Usage; Hose Case Instructions - ICP HANDI-FOAM Instrucciones De Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TEMPERATURE GUIDELINES

The chart below provides a guideline for Storage Temperature, Process (Core) Chemical Temperature, Outside
Application Temperature and Surface Temperature. For specific Process (Core) Chemical Temperature (see the
appropriate TDS).
Storage Temperature
Optimum 75–85°F (24–29°C)
but not < 60°F or > 90°F
(not <16°C or >32°C)
CHEMICAL WARMING & COOLING
• During colder months it may take up to several days
(depending on the size) to warm the chemicals to the
recommended Process (Core) Chemical Temperature (see
appropriate TDS). See Figure 1.
• During hotter months it may take several hours (depending
on the size) to cool the chemicals to the recommended Process
(Core) Chemical Temperature (see appropriate TDS).
• If the cylinders have recently been transported or stored in an unheated environment, a temperature
controlled "box" or a heated blanket is recommended for applications in order to store the refill systems
at a consistent, controlled temperature prior to and during use. An acceptable storage "box" is nothing
more than a small room that is large enough to hold the system(s) being used or conditioned and is
sufficiently insulated and heated to maintain a consistent temperature of 80°F (27°C).
• See page 15 for a complete listing of heated blankets and accessories that ICP offers.

NITROGEN USAGE

• Nitrogen bottles are required for pressurizing the refill systems. They may be obtained for a nominal fee
from a local welding supply house. NEVER use compressed or supplied air.
• "T" nitrogen bottle (300 CF) is required size for Systems 17 & up.
• "G" nitrogen bottle (40 CF) is required size for System 8.
• Up to 3 nitrogen bottles may be needed per System 60 or 100.
• Only 1 nitrogen bottle will be needed per System 17/27 or System 8.
• DO NOT USE compressed air to pressurize the system.
• When nitrogen drops below 500 PSIG (3447.38 kPa) in the bottle, turn off the bottle and regulator and
attach a full nitrogen bottle.
HOSE CARE INSTRUCTIONS
Read all instructions manuals, tags, and labels before operating the hose.
• Safety should be engaged on the Handi-Gun
engaged on Handi-Gun II
should be attached to either Handi-Gun or Handi-Gun II to extend life of dispensing unit.
• Use the hose only for its intended purpose.
• Do not alter or modify this equipment.
• Use only with products manufactured by ICP.
• Lubricate all fittings with petroleum jelly before attaching the hoses to the cylinders.
• Uncoil hose. If heated, always plug unit into a 120V, grounded receptacle no more
than 1 hour before use.
• To avoid excessive heat buildup, NEVER operate the heated hose when it is
coiled or sections of the hose overlap (will cause hot spots).
• Do not fold or kink the hose. Maintain a minimum bend radius of 6" (15.24 cm).
• Do not immerse in water. Hose is water resistant, not waterproof.
• Keep sharp objects away from hose.
• Route hose away from traffic areas, sharp edges, moving parts, and hot surfaces.
• Check hose daily and replace worn or damaged parts immediately.
• Unplug the heated hose from the electrical source when not in use and
at the end of each day.
• After first use, hose must always stay under pressure.
• Always leave chemical in the hose for storage. When the refill cylinders are empty,
connect the hose to a new refill cylinder immediately and spray new chemical into
the hose. This will help prevent moisture from entering the hose.
• All valves should be in the off position when not in use.
• Store hoses in a warm, dry area.
• Fresh chemical must be dispensed through the hose every 7–10 days to prevent loss of performance.
4
Process (Core)
Chemical Temperature
70–85°F (21–29°C)
when not in use. Safety is automatically
®
when trigger is released. During storage, a foam-hardened nozzle
TM
Outside Application
Temperature
40—100°F (4–38°C)
System Size
8 Gal. & Under
17 - 27
60 Gal. & Up
Surface Temperature
40—100°F (4–38°C)
Hours
Days
24–48
1–2
48–72
2–3
72–100
3–5
Figure 1
Handi-Gun
or Handi-Gun II
®
TM
Gun Hose Assembly
Magnum Heated Hose
(for use with Handi-Gun
®
or Handi-Gun II
)
TM
Tabla de contenido
loading