EN
DIRECT DRIVE AGITATOR ASSEMBLIES & AIR MOTORS
DIRECT DRIVE AGITATOR ASSEMBLIES
FOR ASME 2-GALLON TANKS
QMG-416, PLATED STEEL
QMS-430, STAINLESS STEEL
46
47
52
51
53
54
Tank Cover
Shaft Seal (55A) detail
drawing. Open end of seal
faces down (into tank).
Note: Retainer (55B)
required only if tank is used
for vacuum operation.
50
49
INSTALLATION—QMG-416 & QMS-430
1. Unscrew the center plug from the tank cover. Clean the
48
2. Loosen the propeller screw (61) and remove the propeller
3. Make sure the o-ring (54) is fully seated in the groove in
Plug
53
4. If required, loosen the screw (53) in the adaptor to rotate
5. Replace the propeller (60) onto the shaft (58). Make sure
6. Connect agitator to air supply regulator with air hose (62).
DIRECT DRIVE AIR MOTORS
FOR ASME 2-GALLON TANKS
QMG-429, PLATED STEEL
55A
QMS-428, STAINLESS STEEL
55
55B
56
!
51
57
Failure to properly lubricate the air
motor will result in premature motor
failure and will void the warranty. See
lubrication instructions on page 3.
58
60
59
61
62
Connect the agitator to the
air supply as shown using
hose HA-57011.
8 / 12
WARNING
!
Before attempting any installation of agitators onto
pressure feed tanks, the tanks must be relieved of
pressure as high pressure can cause a serious injury.
Pressure is maintained in a pressure tank after the
system has been shut down. Before attempting
removal of fill plug or cover, pressure must be
relieved using the steps on page 3.
sealing surface around the port.
(60).
the adapter (52). Insert the agitator through the port and
screw in until fully tightened.
the motor body to align the hose connection to the required
position. Re-tighten the screw (53).
the screw (61) is aligned with the flat on the shaft and
tighten the screw.
CAUTION
75
76
77
78
77
79
63
64
66
65
67
68
69
70
71
72
68
69
73
66
65
74
77-2990-R3.1 (1/2017)