Care And Cleaning; Troubleshooting - Defiant DFI-5852-BK Guía De Uso Y Cuidado

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Care and Cleaning

To prolong the original appearance, clean the light fixture with clear water and a soft, damp cloth only.
Do not use paints, solvents, or other chemicals on this light fixture. They could cause a premature
deterioration of the finish. This is not a defect in the finish and will not be covered by the warranty.
Do not spray the light fixture with a hose or power washer.

Troubleshooting

Problem
The light will not come on.
The light comes on during the
day.
The light comes on for no
apparent reason.
Possible Cause
The light switch is turned off.
The fuse is blown or the circuit breaker
is turned off.
The light fixture is not properly
attached to the mounting plate, if this is
a new installation (the pins are not fully
seated in the terminal block).
Daylight turn-off (photocell) is in effect.
The circuit wiring is incorrect (if this is
a new installation).
The motion sensor is aimed in the
wrong direction.
The outside air temperature is close to
the same as a person's body heat.
The motion sensor may be installed in a
relatively dark location.
The "Test / Timer" control is in the
"Test" position.
The motion sensor may be sensing
small animals, automobile traffic, or
other heat sources.
The "SENS" control is set too high.
The outside temperature is much
warmer or cooler than a person's body
heat (summer or winter).
The light fixture is wired through a
dimmer or timer.
10
Solution
Turn the light switch on.
Replace the fuse or turn the
circuit breaker on.
Re-install the light fixture
to the base and ensure the
pins are fully seated in the
terminal block.
Recheck after dark.
Verify the wiring is correct.
Re-aim the motion sensor
to cover the desired area.
Increase the "SENS"
setting.
The light fixture is operating
normally under these
circumstances.
Set the "Test / Timer"
control to a timed setting.
Decrease the "SENS"
setting or reposition the
motion sensor.
Decrease the "SENS"
setting.
Decrease the "SENS"
setting.
Do not use a dimmer or
timer to control the light
fixture. Replace the dimmer
or timer with a standard on/
off wall switch.