2 Multiplex Menu
(These extensions of the menus are only available when the extension module MULTIPLEX is linked on the DUPLEX controller)
Where
Parameters
Maximum temperature
tank 1/2
dTMax tank 1/2
dTMin tank1/2
Min speed P. (Triac)
dT FS
Min. collector
temperature
Max. collector
temperature
GDS 1
GDS 2
Maximum temperature
tank 3/4
dTMax tank 3/4
dTMin tank3/4
Heating circuit 1/2
GDS 3/4
Temp Sensor 2
Relay 2 to 8
Relay 9
Relay 10
(►) Multiplex Out
New Fonction in Submenu:
Possibility
15-95°C
4-40°C
2-35°C
30-100%
5-50°C
1 - 99°C
110 – 150 °C
RPS 0-4 or 0-6 or 0-10 bar
VFS 1-12, 2-40, 5-100, 10-200, 20-400
l/min
RPS 0-4 or 0-6 or 0-10 bar
VFS 1-12, 2-40, 5-100, 10-200, 20-400
l/min
T1 to T5 and T7 to 12
15-95°C
4-40°C
2-35°C
Yes/No
RPS 0-4 or 0-6 or 0-10 bar
VFS 1-12, 2-40, 5-100, 10-200, 20-400
l/min
VFS Energy calculation see DUPLEX
manual chapter ―1.16.2 GDS2‖
T1 to T5 and T7 to 12
Schematic/off/thermostat/
difference control unit/plate
heat exchanger/timer
Schematic/off/thermostat/
difference control unit/plate
heat exchanger/timer
scheme/off/thermostat
New Submenu:
(►) Settings
Informations
-
Services
Settings
Operation
Operation h
Temperatures
Multiplex Out
Factory
Setting
65°C
15°C
7°C
60%
P1,P2,P4,P5 (if speed controlled)
35°C
P1,P2,P4,P5 (if speed controlled)
25°C
120°C
Heat protection (system protection)
Not
Grundfoss Flow sensor (VFS) or Pressure
connected
Not
Grundfoss Flow sensor (VFS) or Pressure
connected
Not
Optionnal PT1000 temperature sensor for
connected
65°C
15°C
7°C
No
Grundfoss Flow sensor (VFS) or Pressure
Not
connected
Not
Optionnal PT1000 temperature sensor for
connected
Off
Schematic or functional blocks (floating)
Off
Off
8
See part 4
Function Blocks
Multiplex Out
-
P2
P3
Relay 4
Relay 5
Relay 6
Relay 7
With
All systems
All systems
All systems
All systems
sensor (RPS)
sensor (RPS)
energy calculation
3/4 tank system
3/4 tank system
3/4 tank system
Heating circuit 1/2
sensor (RPS)
energy calculation
Schematic or functional blocks
Schematic or functional block