Using the Thermocouple type K
Connect a TC type K (PH218) to the station and use it as a protection or regulation sensor.
You can define its use mode by means of the "Ext TC mode" option in the "Tool" menu.
You can choose from two work modes:
Regulation: the station regulates the air
temperature automatically to maintain the
External Thermocouple (TC) temperature.
Fix the TC with Kapton Tape (Ref. PH217) as near as possible to the component being worked on.
If Kapton tape is not ESD you must use an ionizer.
IPC* does not recommend exceeding ramp-up rates over 3-4ºC / sec. (5-7ºF / sec) so as to reduce
the risk of thermal stress on the PCB.
* IPC was founded in the U.S. in 1957 as the Institute for Printed Circuits.
w w w.jbctools.com
Protection: the station cuts the air supply off
when the External Thermocouple (TC)
temperature is reached.