Thank you for choosing our product. FAAC is sure that it will give you all the performances you are looking for. All our products are the
result of a long experience in the field of the automated systems.
Thanks to its high powered microprocessor, this 24 V
deceleration and motor control.
Thanks to its integrated encoder, the control unit constantly controls rod position and movement, intervening as soon as a faulty situation
is detected.
The FAILSAFE function makes it possible to detect any faults in the operation of the photocells.
The main operating modes and functions are set by a dip-switch, whereas the adjustment of work and pause times is done by self learning
during programming.
Power supply voltage
Supply voltage of control unit
Absorbed power
Motor nominal power
Accessories max. load
Flashing lamp max. load
Max. load for beam lights
Max. load for courtesy light/indicator light
Operating ambient temperature
Protective fuse
Function logics
Opening / closing time
Pause time
Obstacle detection
Selectable functions
Terminal board inputs
Inputs with connector
Terminal board outputs
Board dimensions
Characteristics of optional batteries
a According to mains voltage, there may be different output values on the board power feed terminals. Before putting into
service, always check if the output voltage on the secondary winding of the transformer is from 20 V~ to 26 V~. Voltage
must always be measured load free.
To ensure people's safety, all warnings and instructions in this booklet must be carefully observed. Incorrect installation
or incorrect use of the product could cause serious harm to people.
•
Make sure that an adequate differential switch is installed upstream of the system as specified by current regulations.
•
On the main power supply, install a thermal breaker with omnipolar switching.
•
Make sure that an adequate earthing system is available.
•
To lay cables, use adequate rigid and/or flexible tubes.
•
Always separate the connecting cables of low voltage accessories from those supplying 230/115 V~, using separate sheaths to avoid
possible interference.
COMPONENTS
CN1
Power supply terminal-board
CN2
Commands terminal-board
JP2
Battery kit connector
JP
Connector for receiver module
JP4
Power supply to RH closing motor
JP5
Power supply to LH closing motor
TR1
Trimmer for adjusting obstacle detection sensitivity
P1
Programming push-button
P2
OPEN channel memory storage push-button
1. DESCRIPTION
control unit for automatic barriers offers a wide range of adjustments, including
2. TECHNICAL SPECIFICATIONS
F1=8 A F2=500 mA F3=630 mA (resettable)
Type of logic - Operation of open command - No mains power supplied
function - Beam lights flashing - Safety devices behaviour
Power supply - Earth - Close - Open - Open/Close - Stop - Safety
Power supply for accessories - On beam lights - Indicator light - Flash-
3. PREPARATIONS
4. BOARD LAY-OUT (Fig. 1)
P
OPEN/CLOSE channel memory storage push-button
F1
Board protection fuse
DL1
CLOSE contact LED
DL2
OPEN contact LED
DL
OPEN/CLOSE contact LED
DL4
STOP contact LED
DL5
Photocells status LED
DL6
OPEN contact signalling LED
DL7
OPEN/CLOSE contact signalling LED
Guide for the installer
230 V~ (+6% -10%) 50 Hz / 115 V~ 60 Hz
24 V~ nominal a
3 W
48 W
500 mA
15 W
15 W
5 W
-20°C +55°C
Automatic - Condo - Manual
Through self-learning during programming
Through self-learning during programming
Trimmer-adjustable
devices - FAILSAFE
Battery kit - Radio connector
light
79 x 158 mm
See kit on price list
COMPONENTS
E604