INSTALL UPPER FLUE MOUNTING
BRACKET
Center of installation
Recommended
distance between
screw holes
3¾"
Center of
Ceiling
installation
Upper flue mounting
bracket slots
1. Drill two
⁄
" diameter holes where shown. Insert drywall
5
1 6
anchors into the holes.
2. Center the bracket over the hood location and flush with the
ceiling. Make sure that the slots of the upper flue bracket are
at the bottom. Secure the upper flue bracket to the wall using
(2) #8 x 1½" mounting screws.
3. Tighten the screws completely. Make sure that the bracket
is tight against the wall.
Ceiling
L
C
1
1
⁄
"
16
7
1
⁄
"
4
Ø 5/16" TYP.
Flush with
the ceiling
C
L
MODELS B5330SS • B5336SS
INSTALL THE HOOD
(Horizontally Ducted Hoods Only)
1. DO NOT REMOVE the protective plastic film covering the
decorative flue and the hood at this time.
2. Lay the back side of the hood flat on a table. Use a piece of
cardboard to avoid damaging the table or the hood.
3. Attach damper / duct connector to top of hood using (4) #8
x 3/8" Pan Head mounting screws.
4. Remove the grease filters by pushing back the metal latch
tab and tilting filters downward to remove.
5. Carefully rotate hood upright.
LOWER FLUE
MOUNTING BRACKET
19"
MAX.
6. To make sure there will be adequate clearance between top
of hood and lower flue mounting bracket for ductwork: Elbow
must be located below lower flue mounting bracket.
7. Align the hood and center it above the hood mounting
bracket. Gently lower the hood until it securely engages the
bracket.
INSIDE BACK OF HOOD
SIDE VIEW
HOLE LOCATIONS
8. With the hood hanging in place, drill through both holes
located in the inside lower back of hood using a 5 ⁄ 1 6" drill bit.
Insert the included drywall anchors into the drilled holes (one
for each hole). Install (2) washers and (2) #8 x 1-3/16" pan
head mounting screws through the hood back and into the
drywall anchors. Verify that the hood is centered and leveled.
Tighten all screws completely.
9. Reinstall grease filters by aligning rear filter tabs with slots
in the hood. Push back the metal latch tab, push filter into
position and release. Make sure filters are securely engaged
after installation.