Cut Off
To receive a correct average weight for the male birds, you must set a Cut off percentage for the
female birds. The Cut off is a percentage set above the female average weight. Any weight above
this percentage will be considered to be a male bird.
It is important to separate the female from male while weighing.
Example:
Female average weight = 2.000 kg.
Cut off = 30%
Using this example, any bird that weights more than 2.600 kg will be consider a male bird.
Since the different in weight between them changes according to age, it is important that change
the Cut Off percentage accordingly.
Cut Off
1. Put the switch in the "Enter" position.
2. Press the "Uniformity" button twice.
3. Enter the percentage through the keyboard.
4. Press "Enter".
Number of birds
The users can enter in the MS Poultry weighing computer memory the number of received birds.
The system will deduct the daily entered mortality so that the user will have the number of live birds
for each plate.
Important: The number of birds must be more than 0 or the MS Poultry weighing computer will not
print out any information from that plate!
Set number of birds
1. Select the desired plate.
2. Set the selector to the "Enter Data" position.
3. Push on the "no. of birds" button.
4. Enter through the keyboard the no. of birds.
5. Push on the "Enter" button
6. Return the selector to the "Display" position.
21