7. Specifications
Orion-Tr Smart Charger
non-Isolated 360 - 400 Watt
Input voltage range (1)
Under voltage shut down
Under voltage restart
Nominal output voltage
Output voltage adjust range
Output voltage tolerance
Output noise
Cont. output current at nominal
output voltage and 40°C
Maximum output current (10 s)
at nominal output voltage
Short circuit output current
Cont. output power at 25°C
Cont. output power at 40°C
Efficiency
No load input current
Shut down current
Galvanic isolation
Operating temperature range
Humidity
DC connection
Maximum cable cross-section
Weight
Dimensions hxwxd
Standards: Safety
Emission
Immunity
Automotive Directive
1) If set to nominal or lower than nominal, the output voltage will remain stable within the specified
input voltage range (buck-boost function).
If the output voltage is set higher than nominal by a certain percentage, the minimum input
voltage at which the output voltage remains stable (does not decrease) increases by the same
percentage.
12/12-30
(360W)
10-17V
7,5V
12,2V
10-15V
30A
40A
60A
430W
360W
87%
< 80mA
< 1mA
200V dc between input, output and case
-20 to +55°C (derate 3% per °C above 40°C)
12V input and/or 12V output models: 1,8 kg (3 lb)
12V input and/or 12V output models:
130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch)
Other models: 130 x 186 x 70 mm
EN 61000-6-2, EN 61000-6-1, EN 55014-2
15
7V
+/- 20mV
2mV rms
Max. 95% non-condensing
Screw terminals
16 mm² AWG6
Other models: 1,6 kg (3.5 lb)
(5.1 x 7.3 x 2.8 inch)
EN 60950
EN 61000-6-3, EN 55014-1
ECE R10-5
12/24-15
(360W)
10-17V
7V
7,5V
24,2V
20-30V
15A
25A
40A
430W
360W
88%
< 100mA
< 1mA
Tabla de contenido
loading

Este manual también es adecuado para:

Orion 24/24-17