TECHNICAL SPECIFICATIONS
Rated voltage
Voltage range
Rated frequency
Voltage circuit self-consumption
Current circuit self-consumption
Instantaneous electrical magnitudes
Recording of maximums (via Modbus)
Monthly closures (up to 12 months)
(via Modbus)
Load curve (via Modbus)
Tariff configuration (via Modbus)
Assigned current or base current
Maximum current
Operating current
Minimum start-up current
Precision
Measurement category
Constant
Meter operation
Optical pulse output
Electrical pulse output
Display
Memory back-up
Backup battery
Clock precision
Summer/winter time changeover
Protection class
Insulation
Casing protection type
Operating temperature
Storage and transport temperature
Relative humidity
Assigned contamination degree
Measurement circuit connections
Current conductor diameter
External conductor terminals
Maximum screw tightening torque
Securing
Casing (Dimension)
DIMENSIONS
162
The PC applications for reading and configuring the CONTAX D-BUS series,
CONTAX ANRET and CONTAX D BUS, are available from our Website, together
with the MODBUS SERIE CONTAX D-BUS REGISTER TABLE document for
advanced use of the MODBUS functions and registers
3 x 230 / 400 Vac
-20% to +15% at rated voltage
50 Hz
< 1 VA, 1 W total
< 0.1 VA, 0.1 W per phase
Phase voltages
Phase currents
Active, reactive, apparent powers
Power factor (cos )
Frequency
Angle between phases
Voltage between phases
Voltage, current, active/reactive energy
Voltage lost
Total or by tariff (up 4)
Active energy, import, export
Reactive energy, import, export
Integration period: 5, 15,30, 60 minutes
Depth: 9000 registers (1, 3, 6, 12 months)
Active and reactive import and export
energies
Up to 6 daily periods with 4 possible tariffs
Distinguish
between
Mo-Tu,
Saturday,
Sunday, Holidays.
Winter season, Summer season
Ib = 10 A
Imax = 100 A (per phase)
from 500 mA to 100 A
40 mA (with power factor 1)
Class 1 according to EN 62053-21
Class 2 according to EN 62053-23
CAT III according to EN 61010-1
800 pulses/ kWh (optical and electrical
outputs)
800 pulses/ kvarh (optical and electrical
outputs)
Static (electronic measurement element)
Flashing LED with constant 800 pulses /
kWh. / kvarh
Opto-coupler
pulses
according
62053-31. Constant 800 pulses/ kWh /
kvarh
Six-digit digital (kWh/kvarh)
EEPROM
Lithium: 10 years at +20°C
±1.2 s/day
Automatic
II under correct installation conditions
Reinforced
between
all
terminals
accessible casing parts
IP 51 on front panel, IP 20 on the rest of the
casing, according to EN 60529
-25 ºC to + 55 ºC
-25 ºC to + 70 ºC
Annual mean < 75 %
Peak values 95 %
3 according to EN 61010-1
Direct by screwed terminals for voltage
circuit, pulses S0 and RS485.
With wire passing-through from the current
conductor across the equipment.
Ø12.5 mm (Current conductor section
depends on the cable type and thickness of
the sheath)
2
2
(2-5-8-11) 0,5 mm
- 2,5 mm
2
(20-21-22-23-24-25) 0,5 mm
- 2,5 mm
0,8 Nm
Symmetrical 35 mm profile (DIN Rail).
According to EN 60715
nine DIN width modules
72
67
SCREEN DISPLAY EXAMPLE
Counter number (001)
Date (30/08/2012)
Total import active energy (7803 kWh) Total import reactive energy (1607 kvarh)
L1 Phase voltage (230,5 V)
L3 Phase voltage (230,5 V)
L2-L3 Phase voltage (399,2 V)
to
EN
L1 Phase current (9,998 A)
and
L3 Phase current (10,02 A)
L2 Phase active power (2,300 kW)
Total active power (6,910 kW)
2
L2 Phase reactive power (1,900 kvar)
Total reactive power (5,709 kvar)
Frequency (50,01 Hz)
04/09.2015
Measurement constant (800 imp/kWh)
Time (11:59:30)
L2 Phase voltage (230,5 V)
L1-L2 Phase voltage (399,2 V)
L3-L1 Phase voltage (399,2 V)
L2 Phase current (10,03 A)
L1 Phase active power (2,309 kW)
L3 Phase active power (2,301 kW)
L1 Phase reactive power (1,907 kvar)
L3 Phase reactive power (1,901 kvar)
Power factor (0,999 inductivo)
Baudrate (9600 bps)
Communication format (none, 8, 1)