Motor Asset Of Line W40 - WEG Motor Scan Manual Del Usuario

Manual de instalación mecánica
Ocultar thumbs Ver también para Motor Scan:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

2.2 POSITIONING OF THE SENSOR - APPLICATION: WEG ELECTRIC MOTOR ASSET
OF LINE W40
The sensor can be installed on W40 motors in the positions shown in
to 280S/M frames, if the terminal box is on top, the sensor must be installed on the side base, as shown in
Figure 2.3 a on page
8; if the terminal box is on the side, the sensor must be installed on top, as shown in
Figure 2.3 b on page
8. In the case of top boxes, if there is any component on one of the side bases, fix it
on the opposite one.
Figure 2.3: Place to install the WEG Motor Scan on W40 motors, frames IEC160 to 280S/M
a) 280L
Figure 2.4: Place to install the WEG Motor Scan on W40 motors, frames 280L and up
For frames 315 and up, see the values for dimension "D" in
a) Top box
125 mm
Table 2.2: Dimension D
Frame
315 (5010/11)
355 (L5010/11)
400 (L5809/10 and L5810/11)
450 (L6808/09)
Positioning of the Sensor for Installation
Figure 2.3 on page
b) Side box
b) 315 and up
Table 2.2 on page
8.
D (mm)
250
290
320
340
8. For IEC 160
Motor center
d
Installation Manual | 8
Tabla de contenido
loading

Tabla de contenido