Troubleshooting; Disclaimer - inti PINO Serie Manual De Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

COMMUNICATION BETWEEN INVERTER AND MPPT
Before using the system: the inverter, the MPPT and the battery must be connected through the communication
RS485 cables. Connect the RS485 communication port of the battery to the inverter and MPPT controller.
NOTE: The RS485 cable is required for a proper communication. The interface is defined as follows:

TROUBLESHOOTING

Check the indicators on the battery frontal panel to determine the status of the battery. A warning state is triggered when a condition, such as
voltage or temperature, is outside the battery's rating. When the battery pack status falls outside of set limits, it enters a warning state. When a
warning is reported, turn off the DC source immediately.
Use the monitoring software to identify the cause of the warning.
Warning alarms
- Battery over voltage
- Battery under voltage
- Battery over temperature
- Batter under temperature
- Battery discharge over current
- Battery charge over current
The fault state is cleared when the battery recovers its normal operation parameters. If the battery does not work correctly and the issue persists,
contact a qualified technician or your distributor.
If the battery or the inverter indicate FAULT or fails to operate, contact your distributor immediately.

DISCLAIMER

- Product modifications, design changes or parts replaced without authorization.
- Changes, or attempted repairs and erasing of series number or seals by a non-authorized technician.
- System design and installations that do not comply standards and regulations.
- Failure to comply with the local safety regulations.
- Transport damage (including painting scratch caused during shipping). In this case, a claim should be made directly to the shipping or insurance
company as soon as the order is unloaded, and the damage is identified.
- Failure to follow any/all the user manual instructions, the installation guide and the maintenance regulations.
- Improper use or misuse of the device.
- Insufficient ventilation of the device.
- The maintenance procedures relating the product have not been followed to an acceptable standard.
- Force majeure (violent or stormy weather, lightning, overvoltage, fire, etc);
- Damages caused by any external factors.
www.intipv.com
B-
B+
RS485
MANUAL DE USUARIO BATERÍA DE PINO / BATTERY PINO USER MANUAL
23
Tabla de contenido
loading

Este manual también es adecuado para:

Ilfp-1536Ilfp-2560Ilfp-3072Ilfp-3840Ilfp-5120Ilfp-512024

Tabla de contenido