1.0 generAl
The DV-28K is a time controlled relay box with
which a maximum of 8 x 600 watt fittings or
10 x 400 watt fittings can be switched.

1.1 TechnicAl dATA

Dimensions
Required voltage
Max. output
Max. output heater
Isolation level
1.2 required (AcTive) volTAge dv-28k
To connect the DV-28K you will preferably need
a 'clean' Group of at least 15 Amp. A 'clean'
group means that this Group will only be used
by the DV-28K. If you do not have a(n) (extra)
'clean' group we advise you to have the DV-28K
installed by a certified installer.
The DV-28K has two 15 Amp (thermal) fuses.
These fuses turn off the DV-28K automatically in
case of an overload and / or a short circuit.
1.3 insTAllATion of The dv-28k
Remove the front panel of the DV-28K housing.
At each corner of the housing you will find
a fixing hole, with which you can mount the
housing onto a (flat) surface with the 4 screws.
CAUTION!
The analogue timer is a sensitive part of the
DV-28K, and is not resistant to hard shocks.
• Place the DV-28K close to your 'clean' group.
At the bottom of the DV-28K you will find
three grounded (230 V) connection cords
DV-28K Binnenwerk PMS.indd 5
Manual DV‑28K
• Install, if needed, a grounded outlet on each
• Plug the two connection cords into the outlets
• The two connection cords are now divided
• Your DV-28K is now connected to the mains
: 210 x 290 x 90mm
: 230 Vac / 50Hz
1.4 connecTing equipmenT To The
: 2 x 15 Ampere
: 15 Ampere
: IP-44
You can connect 8 x 600 watt or 10 x 400 watt
fittings to your DV-28K.
In steps 1.2 and 1.3 you have;
• Connected your DV-28K to a 'clean' group,
• Mounted it onto a flat surface,
• Connected it to the mains voltage.
Now the electric ballasts (fittings) will have to
be connected to the DV-28K. Please read the
installation manual carefully before you connect
the electric ballasts, In order to connect them
properly.
If the electric ballasts have been properly
connected there will be a 230 V cord on each
of the electric ballasts. Plug all the cords of
the electric ballasts into the 8 power outlets
(sockets) on the sides of the DV-28K. You now
have connected the electric ballasts to the
DV-28K.
1.5 The heATer ouTleT
At the front of the DV-28K you will find a (green)
built-in power outlet (socket) for the electrical
heater of max. 15 Amp. This is where you can
place your heater.
of two 'clean' groups.
of each of their 'clean' groups.
over two different 'clean' groups.
voltage.