5.
Apply silicone caulking around edges of coverplate and in any open holes to
provide a watertight seal from rain and moisture.
6.
Insert gaskets into lampholders and screw bulbs into each lampholder
(do not overtighten bulbs).
7.
Turn power on at main fuse/breaker box.
HOW TO OPERATE YOUR FIXTURE
1.
Move slide switch on bottom of the sensor to "TEST".
Set sensitivity slide switch to medium or "M" (Fig. 3).
2.
Turn on the power to fixture. Allow fixture to warm up
approximately 90 seconds before testing. (Lights may
or may not come on during warm-up period, this is
normal.)
3.
Aim sensor head in desired position.
Note: Maintain air spacing between lamps and sensor
head, at least 1˝. Make sure sensor head is positioned with
control switches facing towards the ground.
4.
Walk across the detection zone at the farthest distance
you wish your detector to detect motion.
5.
Adjust sensitivity until you get desired results. For more range,
aim sensor head slightly upwards. For less range, aim sensor
head slightly downward.
6.
Move slide switch to 4 MIN or 12 MIN (AUTO mode), or to one of the three
"NIGHT TIME ON" settings. At dusk, lights will operate in the AUTO or Night
Time On settings.
Call for customer service and/or missing or damaged parts (800-334-6871)
5
Fig. 3