FDI 94 FDI 124 FDI 184 FDI 244 MANUAL DE INSTALACIÓN
CAUTION Be extremely careful not to dent or damage the piping while bending them away from the
unit. Any dents in the piping will affect the unit's performance.
STEP 5: CONNECT DRAIN HOSE
By default, the drain hose is attached to the lefthand side of unit (when you're facing the back of the unit).
However, it can also be attached to the right-hand side.
1. To ensure proper drainage, attach the drain hose on the same side that your refrigerant piping exits the
unit.
2. Attach drain hose extension (purchased separately) to the end of drain hose.
3. Wrap the connection point firmly with Teflon tape to ensure a good seal and to prevent leaks.
4. For the portion of the drain hose that will remain indoors, wrap it with foam pipe insulation to prevent
condensation.
5. Remove the air filter and pour a small amount of water into the drain pan to make sure that water flows
from the unit smoothly.
NOTE ON DRAIN HOSE PLACEMENT
Make sure to arrange the drain hose according to following instructions:
DO NOT kink the drain hose.
DO NOT create a water trap.
BEFORE PERFORMING ELECTRICAL WORK, READ THESE REGULATIONS
DO NOT put the end of drain
hose in water or a container
that will collect water.
51