Danger!
Mortal danger due to electrocution! Whenever work is performed
on the open terminal cover, all poles of the power supply must be
disconnected reliably and protected against being switched on again!
The differential temperature controller Basic Pro is connected
to the power supply via two groups of spring-type terminals which are
visible once the terminal cover is opened.
To introduce the cables, release the two screws on the
strain relief device; if necessary, remove the strain relief device.
In case of flush mounting of the cables, the break-out segments in the housing
base can be removed carefully and the cables routed through these ports.
The spring-type terminals for the power supply, RO1, TS1, TS2, TS3 and TS4
can accommodate solid wires up to a cross section of 1.5 mm
Appropriate stranded wires must be preassembled with cable end sleeves.
For the strain relief device function, TS1 to TS4 require
cable cross sections of at least 5mm, for Power and RO1 at least 7mm.
Terminal block TS1-TS4
Connection to power supply
.
2
Terminal block RO1/Power