3 memorised Wireless sensors, by carrying out the programming proce-
dure, the control unit will emit six confirming sounds warning that the
memory available is full.
E
S
W
S
NABLING OF
OLE
IRELESS
3 - X6):
X
The control unit is supplied by the manufacturer with the Sole Wireless
Sensor enabled. The enabling of the Sole Wireless Sensor can be carried
out as follows: continuously press for 5 seconds the (+) key of a previous-
ly memorised radio-control; the control unit will move Up/Down for 1 sec-
ond to confirm the occurred enabling of the Sole Sensor. It is possible to
repeat the operation to disable the Sole Sensor using the same proce-
dure, but by continuously pressing the (-) key for 5 seconds.
R
OTATION MOVEMENT INVERSION
In case of verifying that when giving the (Up) control on the radio-control
the control unit, instead of associating the ascent of the fastening asso-
ciates the descent, it will be sufficient to repeat the programming proce-
dure by pressing the (Down) key instead of the (Up) key, or invert the
Ascent wire with the Descent wire of the motor.
P
V
ROGRAMMING OF THE
ENETIAN
To activate this functioning modality, move jumper J1, located on the
board inside the plastic container, from position 2-3 to position 1-2. Carry
out this operation with the control unit disconnected from the 230V elec-
tric network.
P
O
ROGRAMMING OF
PERATOR PRESENT FUNCTIONING
To activate this functioning modality, extract Jumper J1 located on the
board inside the plastic container. Carry out this operation with the con-
trol unit disconnected from the 230V electric network.
I
P
NFINITE MOTOR TIME
ROGRAMMING
To set an infinite motor time proceed as follows: keep the SEL key
pressed and simultaneously power the control unit by connecting it to the
electric network until the control unit emits seven confirming sounds. To
restore the motor time at three minutes, repeat the described operation
or carry out the Reset procedure.
R
"SEL"
ESET THROUGH
KEY
To restore the control unit to the default configuration, proceed as fol-
lows: press the SEL key continuously for 5 seconds until the control unit
3
-
ENSOR WITH
KEYS RADIO
CONTROL
F
UNCTIONING
emits five confirming sounds and the operation is completed.
S
S
OUND
IGNALS
(B
F
1 BEEP = First radio-control or Wireless sensor code memorised
E
REE
2 BEEPS = Second radio-control code memorised
3 BEEPS = Programming phase start
4 BEEPS = Programming phase end
5 BEEPS = Restore default configuration
6 BEEPS = Memory end for new radio-control or Wireless sensor.
7 BEEPS = Motor time programming
I
MPORTANT FOR THE INSTALLER
- The device must never be used by children or persons with reduced
physical-psychological abilities, unless supervised or trained on the
functioning and the use modalities.
- Do not allow children to play with the device and keep the radio-con-
trols away from their reach.
- ATTENTION: keep this instruction manual and respect the important
safety prescriptions contained herein. The non compliance with the
prescriptions may cause damages and serious accidents.
- Frequently examine the plant to detect any signs of damaging. Do not
use the device if a repair intervention is necessary.
- In case of needing to replace the cables (powering or motors out-
put) contact experienced and qualified staff.