INTRODUCTION
The QUADRAN 365 Series NDT lamps feature four ultra-hi-flux UV-A LEDs for inspection, plus a convenient
white light LED to illuminate dark work areas. A unique dual-intensity feature on the QDR-365MS and
QDR-365MSBL models provides both high and standard UV-A and white light output for diversity. The lamps'
broad-beam configuration provides an extremely wide coverage area. Models are available with or without
integral black light filters. The lamp handle pin receptacle allows for easy attachment of various Spectroline
mounting accessories for in-line inspection applications (accessories sold separately).The kit includes a
rechargeable NiMH battery pack, AC and DC cord sets, smart AC charger, UV absorbing spectacles and soft
carrying case.
Ultraviolet radiation emitted from this product. Avoid exposure. ALWAYS WEAR PROTECTIVE
CLOTHING. EXPOSURE MAY CAUSE PREMATURE AGING OF THE SKIN AND CANCER.
ALWAYS WEAR PROTECTIVE EYEWEAR; FAILURE TO DO SO MAY RESULT IN SEVERE
BURNS OR LONG TERM INJURY TO EYE. Never look directly into the lamp. Exposure can
cause eye and skin allergy and allergic reactions. Medications or cosmetics may increase
your sensitivity to ultraviolet radiation. Consult physician before operating this product if
you are using medications or have a history of skin problems or believe yourself especially
sensitive to sunlight.
IMPORTANT SAFETY INSTRUCTIONS
• Read all instructions.
• Do not operate the lamp with a damaged cord or if the lamp has been damaged.
• Never use this equipment in any manner not specified in these instructions because the protection
provided by the equipment may be impaired.
• The QUADRAN 365 is not approved for use in hazardous atmospheres. Do not attempt to use it in
areas requiring explosion-proof lighting.
CHARGING
The BP-30 battery pack must be fully charged before first use.
• Check that the voltage characteristics of the battery charger match the voltage of the
AC outlet.
• Align the male connector of the smart charger (BR-150A) to the female connector of the battery pack
(BP-30) and plug them together. Twist the ring on the charger connector to make a tight connection.
• Attach the AC cord supplied to the BR-150A charger and plug the unit into a properly regulated AC
outlet.
• The indicator light on the charger will show Red while it is charging and Green when the battery is
charged. A full charge will take approximately 2 hours.
• After the battery is charged, first unplug the charger from the outlet, then unplug it from the battery
pack.
WARNING: Use only the charger supplied to recharge the battery. Other chargers may harm the battery
and will void the battery's warranty.
For AC Operation
• The connector on the end of the 3.5-ft cord on the lamp handle has an alignment peg, and the
corresponding connector on the AC power cord has a groove. Match the groove to the peg and carefully
screw the associated connectors together. Attach the AC adapter plug to the corresponding AC power
source that complies with the electrical requirements specified on the label.
• The lamp has a three-position rocker power switch (II–UV; O–off; I–white light ) on the back of the
handle. The fan turns on automatically and the light above the switch illuminates green when the UV
LEDs are in use.
• Facing the back of the lamp, the rocker switch on the left of the handle regulates the UV-A LEDs; the rocker
switch on the right regulates the white light LED. Pressing either switch forward produces a higher-intensity
beam; pressing each switch backward produces a lower-intensity beam.
• The QDR-365MS and the QDR-365MSBL standard intensity models have only two switches: the three-
position rocker power switch on the back (II–UV; O–off; I–white light) and the two-position rocker on the
right that regulates the white light intensity.
WARNING: Be sure to use genuine QUADRAN 365 replacement parts. Using another manufacturer's