Carl Valentin FLEXICODE Instrucciones Abreviadas Y Recomendaciones De Seguridad página 121

Ocultar thumbs Ver también para FLEXICODE:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
Key:
Performance information
Key:
Expert parameters
Key:
Printhead down time
Ribbon motor early start
time
Key:
Minimal print speed
Maximum print speed
Taste:
Printhead up time
Key:
Printhead valve reaction
time
Taste:
Print offset border
calculation
Taste:
Ribbon motor stop delay
time
Key:
Field ribbon saving
Rewind speed
sa/mm: The smallest possible distance of two prints with full ribbon save
cmin: Max. number of cycles per minute.
so/mm: Indicates the loss of ribbon save
Password protected menu
Enter password, press key
indicated.
PhDownT = printhead down time in ms:
Is used from ribbon save algorithm to use for the calculation of start time of printhead downward
movement.
REStartT = ribbon motor early start time in ms:
This value is added to the acceleration time of transfer ribbon movement. Time indication for the
time between 'motor reached material speed' and 'printhead burns'.
MinSpeed = minimal print speed:
If the min. print speed is increased, the max. number of cycles is also increased.
USMxSped = use maximum speed:
Use the speed parameter as maximum speed. If the material speed exceeds the maximum
speed the print is interrupted as long as the material speed is again under the maximum speed.
PHupT = printhead up time in ms:
Is used from ribbon save algorithm to calculate if a field ribbon save can be made or not.
PhVReactT = valve reaction time in ms:
The time is calculated when to start with printhead upward movement.
Calcoff = Turn On/Off print offset border calculation:
If this parameter is set to Off, then a smaller offset as the required print offset can be entered.
RibMotStpDlayT = ribbon motor stop delay time
Delay time in ms in which the transfer ribbon motor is still moved with constant speed before
stopping.
FieldRS = field ribbon saving:
Off: Field ribbon save switched off.
Normal: Field ribbon save is only accomplished if the transfer ribbon motor can be completely
stopped.
PHOnly: Only the printhead is moved. The transfer ribbon does not stop.
Strong: Field ribbon save is even accomplished if the transfer ribbon motor cannot be stopped.
Rwind v = rewind speed in mm/s:
Indication of rewind in mm/s.