Temperature Settings: Celsius to Fahrenheit (or Fahrenheit to Celsius)
•∙To∙change∙Re.:∙press∙temp+∙and∙temp-∙simultaneously.

Cooling operation

•∙Press∙the∙"Mode"∙button∙till∙the∙"Cool"∙icon∙appears.∙
•∙Press∙the∙"Temp+"∙or∙"∙Temp-"∙button∙to∙select∙a∙desired∙room∙temperature.∙(62℉-90℉)
•∙Press∙the∙"Fan∙Speed"∙button∙to∙select∙wind∙speed.∙
Heating operation∙(this∙function∙is∙not∙available∙for∙a∙cold-single∙unit)∙
•∙Press∙the∙"Mode"∙button∙till∙the∙"Heat"∙icon∙appears.
•∙Press∙the"Temp+"or"∙Temp-"button∙to∙select∙a∙desired∙room∙temperature.(62℉ - 90℉)
•∙Press∙the∙"Fan∙Speed"∙button∙to∙select∙wind∙speed.∙

Dehumidifying operation

•∙Press∙the∙"Mode"∙button∙till∙the∙"Dehumidify∙Indicator∙Lamp"∙blinks.
Fan operation
•∙Press∙the∙"Mode"∙button∙till∙the∙"Fan"∙icon∙appears.∙
•∙Press∙the∙"Fan∙Speed"∙button∙to∙select∙wind∙speed.
Timer operation
Timer ON setting:
•∙When∙the∙air-conditioner∙is∙OFF,∙press∙the∙"Timer"∙button∙and∙select∙a∙desired∙ON∙time∙through∙the∙temperature∙and∙time∙setting∙buttons.∙
•∙"Preset∙ON∙Time"∙is∙displayed∙on∙the∙operation∙panel.∙
•∙ON∙timer∙can∙be∙set∙for∙any∙time∙from∙0∙to∙24∙hours.
Timer OFF setting
•∙When∙the∙air-conditioner∙ON,∙press∙"Timer"∙button∙and∙select∙a∙desired∙OFF∙time∙through∙the∙temperature∙and∙time∙setting∙buttons.∙
•∙"Preset∙OFF∙Time"∙is∙displayed∙on∙the∙operation∙panel.
•∙OFF∙timer∙can∙be∙set∙for∙any∙time∙from∙0∙to∙24∙hours.
Drainage Internal Tank Water Full Alarm Function
The inner water tank in the air conditioner has one water level safety switch, it controls water level. When the water level reaches an anticipated height, the water full
indicator∙lamp∙lights∙up.∙(If∙water∙pump∙is∙damaged,∙when∙the∙water∙is∙full,∙please∙remove∙the∙rubber∙drain∙plug∙at∙the∙bottom∙of∙unit,∙and∙all∙water∙will∙drain∙outside.)
Continuous Drainge
•∙∙ ∙ W hen∙you∙plan∙to∙leave∙this∙unit∙unused∙for∙a∙long∙time,∙please∙remove∙the∙rubber∙drain∙plug∙from∙the∙drainage∙hole∙at∙the∙bottom∙of∙unit,∙and∙connect∙a∙drain∙hose∙
to∙the∙lower∙fixing∙clip.∙All∙the∙water∙in∙the∙water∙tank∙will∙drain∙outside.∙
•∙If∙water∙pump∙is∙damaged,∙continuous∙drainage∙can∙be∙used,∙and∙under∙this∙condition,∙the∙water∙pump∙is∙not∙activated.∙The∙unit∙can∙also∙work∙well.∙
•∙∙ ∙ I f∙water∙pump∙is∙damaged,∙intermittent∙drainage∙can∙also∙be∙used.∙Under∙this∙condition,∙when∙the∙water∙full∙indicator∙lamp∙lights∙up,∙please∙connect∙a∙drain∙hose∙to∙
the∙lower∙fixing∙clip,∙then∙all∙the∙water∙in∙the∙water∙tank∙will∙drain∙outside.∙The∙unit∙can∙also∙work∙well.∙