INSTALLATION
STEP
6
Install
the
Door
Control
Locate door control within sight of door, at a minimum
height of 5 feet (1.5 m) where small children cannot reach,
away from moving parts of door and door hardware.
1 .Strip 1/4" (6 mm) of insulation from one end of bell wire
and connect to the two terminal screws on back of door
control by color: white to 2 and white/red to 1.
2. Fasten the Door Control Button securely with 6ABxl -
1/2" screws. If installing into drywall, drill 5/32" holes
and use the anchors provided.
3. Run bell wire up wall and across ceiling to motor unit.
Use insulated staples to secure wire in several places.
Do not pierce wire with a staple, creating a short or
open circuit.
4. Connect the bell wire to the terminal screws on the
motor unit panel: white to 2; white/red to 1.
5. Position the antenna wire as shown.
6. Use tacks or staples to permanently attach entrapment
warning label to wall near door control, and manual
release/safety
reverse test label in a prominent location
on inside of garage door.
NOTE: DO NOT connect power and operate opener at
this time. The trolley will travel to the full open position but
will not return to the close position until the sensor beam
is connected and properly aligned.
To prevent )ossible SERIOUSINJURYor DEATHfrom
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLYto 24 VOLTlow voltage wires.
To prevent )ossible SERIOUSINJURYor DEATHfrom a closing
garage door:
• Install door control within sight of garage door, out of reach
of children at a minimum height of 5 feet
(1.5 m), and away from all moving parts of door.
• NEVERpermit children to operate or play with door control
push buttons or remote control transmitters.
• Activate door ONLYwhen it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keepgarage door in sight until completely closed.
NEVERpermit anyoneto cross path of closing garage door.
Outside
Keylock Accessory Connections
To opener terminal screws: white to 2; white/red
to 1.
HARDWARE
SHOWN ACTUAL
SIZE
Screw 6ABx1-1/2"
Insulated
Lighted Door Control Button
Drywall Anchors
Staples
I
Terrem 'wnsa ' _
(BACK VIEW)
DOOR CONTROL
BU7q-ON
2-Conductor
Bell Wire
Opener
Terminal Screws
Back Panel
/
of Opener
Antenna
17