Commissioning
24 V
The pump control is activated or deactivated directly at the base station, or with an Alpha IP room
control unit Display.
6.4.1 Activation/deactivation of the pump control (base station)
1. Press the Select key (B) of the Alpha IP base station approximately for 4 seconds, until the LED of
heating zone 1 flashes in green:
Duration in seconds
0,1
0,2
0
HZ1
Duration in seconds
0,5
1,0
0
HZ1
2. Toggling the pump from active to inactive or vice versa: Press the Select key (B) for 4 seconds.
3. Leaving the menu without changes: Press the Select key shortly.
6.4.2 Activation/deactivation of the pump control (Room control unit Display)
With the Alpha IP room control unit Display, different parameters can be assigned to the pump control.
For this, the parameter P025 in menu UnP1 (see section 8: Configuration) must be changed according
to the requirements.
For parametrisation, one Alpha IP room control unit must have been taught in to heating zone
1. This device can be used for further heating zones.
7
Commissioning
For the commissioning of the Alpha IP base station, at least one Alpha IP room control unit Display,
Display S or Analog must be taught-in to the base station. As an alternative, the base station can be
integrated to the Alpha IP Access Point via the app into the Alpha IP system. If used without Access
Point, the base station must be configured via the Alpha IP room control unit Display.
1. Establish the electrical supply of the Alpha IP base station.
9 All heating zones of the base station are activated for 10 minutes in order to unlock the first-open
function of connected actuators.
24
L1
L2
1
2
1
2
1
2
1
24V
AC
L
N
Display
0,3
0,4
1,5
2,0
230 V
HZ1- HZ10: 24V 1A/HZ
2
1
2
1
2
1
2
1
2
1
2
1
Relay HZ1 230 V ~ 3 (1) A
2
1
2
1
2
1
N
2
L
1
2
1
1
2
2
1
2
Meaning
Pump inactive
(UnP1: P025, value 4)
Pump active
(UnP1: P025, value 0)
Relay
1
2
1
2
1
2
1
2
1
2