Important; Characteristics; Integral Parts Of The Flat Automatic Multiport Valve System (Vsaf); Dimensions - Astralpool 43512-1000 Manual De Instalación Y Funcionamiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
WARNINGS FOR THE ASSEMBLY AND MAINTENANCE WORK.
For the set up and installation of the automatic valve the installation regulations of the country in question must
be respected.
Special attention must be paid so that in no circumstances does water get into the electronic circuit of the
automatic valve.
Never come into contact, not even by accident, with the moving parts of the automatic valve while it is working,
and / or after it has totally stopped.
Before going ahead with any electrical or electronic maintenance work, make sure that all start up devices are
blocked.
It is recommendable to follow the following steps before carrying out any operation on the automatic valve:
1.
Disconnect the electricity supply to the valve.
2.
Block all start up devices.
3.
Check that there is no tension / voltage in the circuits, not even in the auxiliary and supplementary
services circuits.
The list set out should be considered as indicative, and does not rule out other security measures, it being
possible that there exist specific safety regulations under other legislations.
IMPORTANT - Due to the complexity of the cases dealt with, the instructions for the installation, use and main-
tenance of the valve contained in this manual do not set out to examine all the possible and imaginable service
and maintenance cases. If supplementary instructions were necessary, or if specific problems occurred, do not
hesitate to contact with the distributor, or directly with the manufacturer of the valve.
Our automatic valves can only be installed in swimming pools or ponds that comply with the regulation HD
384.7.702. If there is any doubt about this compliance we ask you to consult your specialist.
Check the contents of the packaging.

2. CHARACTERISTICS

2.1
Parts making up the automatic multiport valve system
The VSAF is made up of four integral parts:
1. The FLAT activator 1
2. The central axis
3. The pressure switch unit
4. The multiport valve
2.2

Dimensions

225
TOP
5
ASTRALPOOL
2
3
307
SIDE
®
1
4
122.5
190
Tabla de contenido
loading

Este manual también es adecuado para:

43513-1000

Tabla de contenido