WIRING CONNECTIONS
Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
1. While making wiring connections, support the heater
assembly on the bottom of the rough-in frame.
2. For 120 Volt operation, make wiring connections as shown
in Figure 4.
3. For 240 Volt operation, make wiring connections as shown
in Figure 5.
4. Use wire nuts to make connections. Insulate all
connections with electrical tape.
SECURING THE HEATER
1. Dress all wiring back to into junction box.
2. Locate center holes in housing flange and align with
mounting holes in grille.
3. Use two provided screws to attach grille to housing.
120vAC
GREEN
GROUND
4
YELLOW
3
WHITE
2
RED
1
BLACK
240vAC
GREEN
GROUND
4
YELLOW
3
WHITE
2
RED
1
BLACK
3
GREEN OR BARE
GROUND
WHITE
BLACK
GREEN OR BARE
GROUND
RED OR WHITE
NO
CONNECTION
NO
CONNECTION
BLACK
FIGURE 4
FIGURE 5