Recessed BINOPTIC or TEMPOMATIC models (fig. E):
FOR WALLS
• Make a recessing space, minimum size 188 x 162 x 70mm, so that the bottom of the spout is
approximately 200mm above the washbasin surface.
• Allow a recess for the water supply pipes and electrical supply to connect to the electronic housing.
• Solder two Ø12mm pipes onto the connectors. It is possible to connect the water supply to the top
of the box by turning it upside down.
• Cover with a Ø18mm sheath.
• Push the 4 mounting brackets on the housing gently towards the rear. Two holes in the bottom
of the stainless steel housing will allow its eventual attachment via the base.
• Seal the housing unit, tubes and the sheath.
• Seal the inside and lower edge of the housing unit with mastic to prevent any water leaking
into the wall. Position the silicone seal behind the stainless steel wall plate to ensure a waterproof seal
between the wall plate and the wall. Leave a drainage point to allow any residual water to drain away.
FOR DRY WALLS
• To attach the housing unit using the 4 mounting brackets, strengthen the dry wall with 2 support rails.
• Seal the inside and lower edge of the box with mastic to prevent any water leaking into the wall.
Position the silicone seal behind the stainless steel wall plate to ensure a waterproof seal
between the wall plate and the wall. Leave a drainage point to allow any residual water to drain away.
FIXING THE COVER
• Once the wall has been finished, attach the rails onto the stainless steel case with 4 screws,
ensuring that they are level.
• Install the hydraulic unit.
• Feed the sensor and solenoid valve cables through the sheath.
• Connect the flexible to the spout and the solenoid valve.
• Snap the cover onto the upper rail. After testing, tighten the 2 screws under the cover to tighten
in place using a 2.5mm Allen key.
• Connect the solenoid valve and complete the installation as shown in the CONNECTION section.
THE INSTALLER MUST ENSURE THAT:
• THE RECESSING AREA IS WATERPROOF TO PREVENT ANY INGRESS OF WATER;
• ANY WATER ACCIDENTALLY ENTERING THE RECESSING AREA (E.G. CONDENSATION, RUN OFF,
LEAKS, ETC.) HAS A DRAINAGE POINT TO PREVENT STAGNATION;
• THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL
OR THE WALL PLATE AND THE MIXER/TAP AT LEAST ONCE A YEAR, AND MORE FREQUENTLY
IF NECESSARY, AND MAKE GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall. DELABIE cannot be held responsible
for any ingress.
FOR FURTHER INFORMATION PLEASE CALL TECHNICAL SUPPORT (SEE BELOW FOR CONTACT DETAILS).