NOVA photocells may be installed very close together thanks to SYNCHRONIZATION.
SYNCHRONIZATION is guaranteed for up to 4 pairs of photocells by setting the SW1 micro-
switches on every TX transmitter and SW2 on every RX receiver as shown in the diagram
below.
NOTE: for the correct functioning of the syncronization, at least one of the pair of photocells must have both the dip switches in the OFF mode (see TX1
and RX1).
In case the power supply is 12-24 Vac, the wiring must be carried out as per diagram.
ATTENTION: if the power supply is inverted even just on TX or RX, the syncronization will not be carried out correctly.
TX1
TX2
TX3
TX4
Connect the SYNC terminals and the transmitters in the system to each other as in the
diagram to create synchronization.
RX1
RX2
RX3
RX4
Power 12/24V ac/dc to connect to
terminals AD+ AD- on the RIB control
panels