EB TECHNOLOGY TRANSCEIVER-TXMINI Instrucción página 14

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

TRANSCEIVER v2
Operating system
Memorization with continous testing
of the TX. DIP-1 OFF in Tx and Rx
The system is a safety device according to the laws
only if the test will be done at the beginning of each
cycle the inputs.
TEST INPUTS
Connect to the test connections COMMON
(negative) and FOTOTEST output from the control
unit of the gate.
With DIP-2 of the RX in OFF the Receiver will
check the transmission of all TX when there is
tension in all inputs.
DIP-2 of the RX in ON position, will check all
transmissions in case of lack of tension.
In this case, there is an active check of the safety
and of the installation according to the law, the
receiving part of the TX is always activated, and
there is a higher consumption of the batteries.
In case of 2 batteries LR06 AA 1,5 V
the battery life is approximately 12 months.
Test
When the control panel activates the TEST with TEST INPUT (see previous connections), out 1 and out 2 will
go open circuit and return to close circuit when the test is complete.
OUT1 and OUT 2 of the receiver
The outputs are N.C. or 8,2K when not in alarm. Each output has a l.e.d. which is normally lit on. If you use an
optical 8,2K output and it is activated the contact is normally closed. To select the output use JUMPER N/R1
NC/ NA and JUMPER C/R2 NC/NA below the relays.
Memorization with periodic testing of
the TX DIP -1 in ON in Tx and Rx
There is a periodic check available called "CHECK
OF THE CONDITION" of the safeties,
receives the signal each 12 sec. If after 30 seconds
the receiver doesn't receive any signal from the
transmitter, the RECEIVER switches on the alarm
output for the corresponding TX.
Installation
To test this operating mode put DIP-1 OFF in the
transmitter and in the receiver, after completing
your test, put DIP-1 ON in the transmitter and in the
receiver for normal operation.
When you switch on the installation, the receiver will
wait for the constant transmission of the TX, and if
successful will activate the output in 10 seconds, and
if the TX are not found or are not working, the receiver
will check all the transmitters again. (red L.E.D.
turns off). This is also for the TEST (PHOTOTEST)
from the control unit, the output will close within 10
seconds. This may delay the opening of the gate by
10 seconds.
With this installation the battery life will be up to 24
months.