CALIBRATION OF THE WEIGHT
display
LF 1
CAL Z
150.00 kg
150.00 kg
150.00 kg
CONFIGURATION
display
FIRST STEP
262144
SECOND STEP
1 0 0 0 0 1
A B C D E F
THIRD STEP
000000kg
FOURTH STEP
dP 0.0
FIFTH STEP
diV 01
46
LF 1
The calibration can be done with any weight, but the weight ca not be inferior to 1/100 of the
maximum capacity and it must also never be exceeded.
•Press the key
to start the calibration of zero ( press
the menu LF1)
•Use
,
and
calibration will be done. ( press the key
•Place the required weight on the scale as it is indicated in the display.
•Once everything is steady, press the key
tion and go back to the menu LF1).
THE CALIBRATION IS GOING TO FINISH AND THE SCALE WILL GO VACK TO THE WEIGHING MODE AUTOMATICALLY.
LF 2
•DISPLAY OF THE INTERNAL COUNTING
•POSSIBLE VALUES OF THE PARAMETERS
A: Metric system
B: American system
C: other unities
D: PCS
E: double range
F: units of calibration
lb oz cannot be selected as unities of calibration.
The scale won't let us continue up to the next step if there is a mistake during the programming.
•Use
,
and
•Use the Keys
,
d 0.00
•Use
to select the DIVISION:
diV 01, diV 02, diV 05, diV10, diV 20, diV 50
DESCRIPTION AND SEQUENCE OF USE
0 ~ 9
,
and then press
to exit the calibration and go back to the menu LF1)
to calibrate it ( press the key ESC to exit the calibra-
DESCRIPTION AND SEQUENCE OF USE
0:NO
1: kg
0:NO
1: lb
0:NO
1: TW kg
0:OFF
1: ON
0:OFF
1: multi interval
1:use metric
unities
0 ~ 9
,
and then press
to change the position of the DECIMAL POINT.
d 0.000
d 0.0000
USER'S MANUAL BR15
To exit the calibration and go back to
to introduce the weight with which the
2:T
3:g
2:lb oz
2:HK kg
3:VISS
2:multi range
2:use american unities
to introduce THE MAXIMUM CAPACITY.
0.00000
EN