Type
Nominal voltage
Nominal capacity
Usable capacity
DOD
Charge voltage
Discharge voltage
Recommended charge/discharge current
Max. Charge/Discharge current
Peak charge/discharge current (15 s)
Working temperature
Dimensions WxHxD
Weight
Design life (25℃)
Cycle life (25℃, 90% DOD)
Communication interfaces
Certifications
Max. Inverter efficiency
Euro efficiency
MPPT efficiency
Overload protection
Overtemperature protection
Overvoltage/undervoltage protection
Overvoltage protection category
DC isolation impedance
DC injection monitoring
Anti-islanding protection
Overcurrent PV protections
Overcurrent battery protections
AC lines protection
EPS lines protection
Inverter topology
Protection class
Operating temperature range
Noise emission
Standby consumption
Dimensions WxHxD
Weight (with only one module)
EMC Standard
User manual ecoSMART e-system
Battery module
Charge
Discharge
440x88,5x410
Efficiency
Safety and protections
III (grid side) II (PV side)
DC 12A fuses (positive and negative pole)
Others
720x1058x710
44
LiFePO4
48
V
2.400
Wh
2.200
Wh
90
%
52,5-54
V
45-54
V
25
A
50
A
100
A
0-50
℃
-10-50
℃
mm
24
Kg
>10
years
>4.500
cycles
RS232, RS485, CAN
TüV/CE/UN38.3
97,6
%
97
%
99,9
%
Yes
Yes
Yes
Yes
Yes
Yes
DC 50A fuse
External installation
External installation
Transformerless
IP20 (indoor use)
-20-60
℃
<40
dB
<42
W
mm
118
Kg
IEC61000-6-1/2/3/4