Dyson AB12 Guia De Instalacion página 7

Ocultar thumbs Ver también para AB12:
Idiomas disponibles

Idiomas disponibles

4
Connecting to terminal block.
L
N
WArning: risk of electric shock!
Ensure power is not connected.
1. Ensure the electrical wiring does not sit above
the electrical wiring guide from the electrical
wiring entry point to the terminal block. If the
electrical wiring sits above the guide walls it
may interfere with main components, prevent
the security screws being fitted correctly, or
risk the main body being forced onto the
backplate, causing damage.
2. Unscrew the electrical wiring clamp from
the backplate. Remove the electrical wiring
terminal block holder.
3. Open the flap on the terminal block holder.
Secure the line, neutral and ground wires
into the correct terminal block locations as
6mm
indicated on the terminal block holder.
4. Verify the connections are correct before
proceeding.
5. Close the flap on the terminal block holder
and fit it into the backplate.
6. Screw in and secure the electrical wiring
clamp.
CAution: Do not overtighten and crush the
electrical wiring.
5
Attaching main body.
CAution: Do not overtighten screws.
1. Hook the main body of the unit over the top
rim of the backplate.
2. Swing the main body of the unit down onto the
back plate. (For installations with the electrical
wiring entry on the side, ensure that the side
bracket seal is correctly seated against the
main body.)
3. Insert and tighten the (2) security screws
into the side of the main body as illustrated.
Recommended torque of 0.5-0.7NM.
4. Turn power on.
5. Test unit for correct operation.
7
Do not use sealant when fixing the unit to the
wall.
Do not paint/coat the main body or place
graphical stickers on it or this may damage the
anti-microbial surface.