3.4 - Connecting control buttons and key switch
normally open contacts (the APCH or aped LEDs come on when the selector or the buttons connected in parallel are operated) the APCH input controls
opening or closing the gate completely, the APED input controls partial gate opening or closing:
3.5 - Connection of timer or detector with magnetic induction
with normally open contact (the open LED comes on when the timer or magnetic induction detector are operated) the OPEN input commands full opening
of the gate, until the contact is closed, the gate opens and remains in the open position, the APCH, APED commands and saved remote controls are not
active until the contact is reset from closed to open, after the automatic closing time set with the PAUSE trimmer, the gate closes, this input is used to
open and hold open the gate at the times of greatest influx:
3.6 - Connecting photocells
Normally closed contact (when the photocells are not engaged the PHOTO LED must be on), when this input trips during closing it reverses the move-
ment, if not used then jumper between COM. and PHOTO, you must observe the polarity of the power supply for the photocells:
CN1
18
Pulsante comando APCH
Pulsante comando APED
CN2
17 18 19 20 21 22 23
+
- -
COM
FOTO
COM
N.O.
12
1
11
2
10
3
9
4
8
7
5
6
Fig. 8
TIMER
RX1
+
-
C NC NA
EN
COM
N.C.
N.C.
N.O.
Fig. 7
RX2
TX1
+
-
C NC NA
+
-
TX2
+
-
Fig. 9