Venting Requirements; Important - Amana NGD5500TQ Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Must include a shutoff valve:
In the U.S.A.:
An individual manual shutoff valve must be installed within
six (6) feet (1.8 m) of the dryer in accordance with the National
Fuel Gas Code, ANSI Z223.1.
In Canada:
An individual manual shutoff valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shutoff valve be installed within six (6) feet (1.8 m)
of the dryer.
The location should be easy to reach for opening and closing.
A
B
³⁄₈
A.
" flexible gas connector
³⁄₈
B.
" pipe to flare adapter fitting
¹⁄₈
C.
" NPT minimum plugged tapping
D. ½" NPT gas supply line
E. Gas shutoff valve
Gas supply connection requirements
Use an elbow and a ³⁄₈" flare x ³⁄₈" NPT adapter fitting
between the flexible gas connector and the dryer gas pipe, as
needed to avoid kinking.
Use only pipe-joint compound. Do not use TEFLON
This dryer must be connected to the gas supply line with a
listed flexible gas connector that complies with the standard
for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
Burner Input Requirements:
Elevations above 10,000 ft (3,048 m):
When installed above 10,000 ft (3,048 m) a 4% reduction of
the burner Btu rating shown on the model/serial number plate
is required for each 1,000 ft (305 m) increase in elevation.
Gas supply pressure testing
The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
½ psi.
Dryer Gas Pipe
The gas pipe that comes out through the rear of your dryer
has a ³⁄₈" male pipe thread.
A
³⁄₈
A.
" NPT dryer pipe
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
C
E
D
®
1¼"
(3.2 cm)
9¼"
(23.5 cm)
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING:
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling or a concealed space of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid or flexible
tape.
heavy metal vent.
Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.
If this is a new vent system
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE™ venting products are recommended.
DURASAFE™ vent products can be purchased from your
dealer or by calling the toll-free number listed on the cover of
the Dryer User Instructions. For more information, see the
"Assistance or Service" section of the Dryer User
Instructions.
Rigid metal vent
For best drying performance, rigid metal vents are
recommended.
Rigid metal vent is recommended to avoid crushing and
kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for
cleaning.
Flexible metal vent must be fully extended and supported
when the dryer is in its final location.

Venting Requirements

WARNING
Fire Hazard
To reduce the risk of fire, this dryer MUST BE
4"
10.2 cm
4" (10.2 cm) heavy metal exhaust vent
5
Tabla de contenido
loading

Tabla de contenido