Advanced Functions - Omega HH-2000 Serie Manual Del Usuario

Tabla de contenido
OMEGAnet On-Line Service
http://www.omega.com
USA:
ISO 9001 Certified
Canada:
For immediate technical or application assistance:
USA and Canada:
Mexico and
Latin America:
28
Benelux:
Czech Republic:
France:
Germany/Austria:
United Kingdom:
ISO 9002 Certified
omega.com
®
®
®
Internet e-mail
Servicing North America:
One Omega Drive, Box 4047
Stamford, CT 06907-0047
Tel: (203) 359-1660
FAX: (203) 359-7700
976 Bergar
Laval (Quebec) H7L 5A2
Tel: (514) 856-6928
FAX: (514) 856 6886
Sales Service:1-800-826-6342 / 1-800-TC-OMEGA
Customer Service: 1-800-622-2378 / 1-800-622-BEST
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Tel: (95) 800-826-6342
FAX: (95) 203-359-89-8
En Español: (95) 203-359-7803
Servicing Europe:
Postbus 8034, 1180 LA Amstelveen, The Netherlands
Tel: (31) 20 6418405
FAX: (31) 20 6434643
Toll Free in benelux: 0 800 0993344
ul. Rude armady 1868, 73301 Karvina-Hranice
Tel: 420 (69) 6311899
FAX: 420 (69) 6311114
Toll Free: 0800-1-66342
9 rue Denis Papin, 78190 Trappes
Tel: (33) 130-621-400
FAX: (33) 130-699-120
Toll Free in France: 0800-4-06342
Daimlerstrasse 26, D-85392 Deckenpfronn, Germany
Tel: 49 (07056) 3017
FAX: 49 (07056) 8540
Toll Free in German: 0130 11 21 66
One Omega Drive, River Bend Technology Centre,
Northbank, Irlam, Manchester M44 5EX, England
Tel: 44 (161) 777-7711
FAX: 44 (161) 777-6622
Toll Free in England: 0800-488-488

ADVANCED FUNCTIONS

The following additional functions apply to models
HH2001KL, HH2001LTC, HH2001PL, HH2002AL
LOGGING
These models have functions that enable the user to store and
retrieve up to 250 readings and output such to a PC or Epson
compatible printer via Omega's Infra-red HHP-2000DL. Omega
also offers MLWIN, a customised Windows™ software package.
Note: Some functions may be inhibited while information is stored
in either Auto, Manual or Max/Min modes. This is to prevent
inadvertent parameter mixing whilst in any of the above modes.
To re-activate these functions please delete any stores
information by following the "Output of data" section.
SETTING INTERNAL CLOCK
Press d
ecimal point
(•) key and the
appear on display with the current year and month settings
(YYMM).
SM
SM
Key in new year and month if desired and press
SM
Display will show current date of month setting (DD). Key in new
value if desired and press
Display will show current hours and minutes setting (24 hour
clock). Key in new values if desired and press
Instrument will then return to normal mode.
LOGGING ON DEMAND
This function allows readings to be stored as and when required.
A maximum of 50 readings can be stored this way.
When ready to store a reading press
and will appear on the display. It is possible to enter up to a
0
four digit reference number including decimal point. Press
to enter and store reading, time, date and reference number.
Instrument will return to standard mode, however
remain on display until data is erased.
PRESET INTERVAL LOGGING
This function allows readings to be taken automatically at a preset
time interval.
NOTE: If data is already stored, as signified by the
symbols appearing on display, this function will not operate.
Press
key.
NE
symbol and
Enter required time interval in hh:mm (ie, in order to take a
reading every 1 minute, key in 0001) and press
reading will return to display and
display.
Instrument will continue logging until a maximum of 250 readings
are taken or data is down-loaded.
OUTPUT OF DATA
This feature will only function if either the
displayed.
To view data press
key, then and
reading will be displayed. Press
stored readings and any other key to return to normal mode.
and
NE
symbols will
key to accept.
key to accept.
key to accept.
key.
,
NE
symbols
key
symbol will
or
0000
will appear on the display.
key. Current
symbol will remain on
or
symbols are
1
keys. The first stored
key to view successively
5