Omega HH-2000 Serie Manual Del Usuario página 4

Tabla de contenido
recalled when the instrument is next powered up.
NOTE: The channel selection will not operate if the display is in
HOLD
or
MAX/MIN
C/F SELECTION
Models HH2001A, HH2001K, HH2001KL, HH2001P,
HH2001PL, HH2002A, HH2002AL, HH2002K
Select the desired temperature scale by pressing
selected scale is confirmed by
is retained when the instrument is switched off.
NOTE: Models HH2001K, HH2001T and HH2001LTC are
supplied pre-set and will display either
RANGE LOCK
Models HH2001A, HH2001K, HH2001KL, HH2001P,
HH2001PL, HH2002A, HH2002AL
All instruments have a 0.1° resolution from -
199.9° to +392.8°F,
the display to a 1° resolution press the
mode press the
display.
THERMOCOUPLE SELECTION
Models HH2001A, HH2002A, HH2002AL
Press
KTJNRS
J, N, R
or on the display.
S
4
This selection is retained when the instrument is switched off.
MAX/MIN RECORDER
Models HH2001A, HH2001K, HH2001LTC, HH2001P,
HH2001PL, HH2002A, HH2002AL, HH2002K
Press
key to start. The instrument will display alternating
symbols and current reading. Press again to display the
maximum temperature reading and
Press again to display the minimum temperature reading and
symbol will be displayed. Press again to return to the actual
temperature display.
Press
X
key to display the average temperature since the MAX/MIN
mode was activated and
X
key again to return to actual temperature display.
NOTE: To reset MAX/MIN recorder function switch the instrument off.
NOTE: Some functions may be inhibited while information is stored in
either Auto, Manual or Max/Min modes. This is to prevent
inadvertent parameter mixing whilst in any of the above modes. To
re-activate these functions please delete any stores information by
following the "Output of data" section.
SENSOR OPEN CIRCUIT OR
OVERRANGE/UNDERRANGE INDICATION
If the sensor is open circuit, the display will show
condition exists.
NOTE: If
MAX/MIN
even after the open circuit has been cleared.
If overrange or underrange occurs the instrument will display
mode.
key. The
°C
or
°F
symbol on the display,and
°C
or
°F
only.
199.9° to +199.9°C/-
and a 1° resolution outside this range. To fix
A/R
key. To cancel the
A/R
key again and
A/R
will be shown on the
key to select the available type as shown by
K, T,
symbol will be displayed.
symbol will appear on display. Press
O-C
as long as
mode is selected,
O-C
will not be cleared
Out
An OMEGA Technologies Company
Servicing USA and Canada: Call OMEGA Toll Free
USA
One Omega Drive, Box 4047
Stamford, CT 06907-0047
Telephone: (203) 359-1660
FAX: (203) 359-7700
Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA
Customer Service: 1-800-622-2378 / 1-800-622-BEST
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN
TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Servicing Europe: United Kingdom Sales and Distribution Centre
25 Swannington Road, Broughton Astley,
Leicestershire LE9 6TU, England
Telephone: 44 (1455) 285520 FAX: 44 (1455) 283912
The OMEGA Complete Measurement and
Control Handbooks & Encyclopedias
Temperature
Pressure, Strain & Force
Flow and Level
pH and Conductivity
.
Call for your FREE Handbook Request Form today: (203) 359-RUSH
®
Canada
976 Bergar
Laval (Quebec) H7L 5A1
Telephone: (514) 856-6928
FAX: (514) 856-6886
SM
SM
SM
4
Data Acquisition Systems
4
Electric Heaters
4
Environmental Monitoring
and Control
29
Tabla de contenido
loading

Tabla de contenido